IBM Power775 Service Procedure page 15

Time of day (tod) battery service procedure
Hide thumbs Also See for Power775:
Table of Contents

Advertisement

Power775 Time of Day (TOD) Battery Service Procedure
Use the procedure "Appendix: Power775 BPC FSP Command Line Procedure"
STEP 20
in Section 5 of this document).
the RTC by executing the following commands on the BPC FSP Command line.
I. Determine the current Time Of Day (TOD) settings by executing the following command on
the BPC FSP Command line.
rtim timeofday
II. If the TOD needs to be changed, execute the following command on the BPC FSP Command
line.
rtim timeofday yyyyMMddhhmmss
Where:
• Confirm any changes by repeating the rtim timeofday command as necessary
• If time of day settings can not be properly set contact next level of support.
III. Log out of BPC FSP ASM
PN: 41U8496, EC N44172
Verify the accuracy of the Real Time Clock (RTC) and if necessary reset
yyyy: Year (0001 - 9999)
MM:
Month (01 - 12)
dd:
Day (01 - 31)
hh:
Hour (00 - 23)
mm:
Minute (00 - 59)
ss:
Second (00 - 59)
Page 15 of 23