7. Indirect Pythagoras Measurement ①
1) Press the
button to switch to the indirect Pythagoras
measurement ①
.
2) According to the flashing edge, point the laser at the first
point of the target, and press the
kbutton to measure
the first hypotenuse.
3) Rotate to the direction perpendicular to the target with
the set reference as center, and press the
measure one right-angle side.
4) Rotate to the third point of the target with the same
reference as center, and press the
the second hypotenuse.
5) The calculation result of the length between the first point
and the third point is displayed at the bottom of the screen.
8. Indirect Pythagoras Measurement ②
1) Press the
button to switch to the indirect Pythagoras
measurement ②
.
2) Point the laser at the first point of the target, and press
the
button to measure the first hypotenuse.
3) Rotate to the second point of the target with the set
reference as center, and press the
the second hypotenuse.
4) Rotate to the direction perpendicular to the target with
the same reference as center, and press the
to measure the third right-angle side.
5) The calculation result of the length between the first point
and the second point is displayed at the bottom of the
screen.
9. Auto Horizontal Measurement
1) Press the
button to switch to the auto horizontal
measurement
.
2) According to the flashing edge, point the laser at the first
point of the target, and press the
button.
3) The angle degree between the hypotenuse and the
horizontal edge, the length of the hypotenuse edge, the
length of the horizontal edge, and the length of the vertical
edge will be displayed on the screen from top to bottom.
10. Auto Vertical Measurement
1) Press the
button to switch to the auto vertical
measurement
.
2) According to the flashing edge, point the laser at the first
point of the target, and press the
button to measure
the first hypotenuse.
3) Rotate to the second point of the target with the set
reference as center, and press the
the second hypotenuse.
4) The calculation result of the length between the first point
and the second point is displayed at the bottom of the
screen.
IV. Standard Accessories
Quantity
Accessories
1.2V (AAA) NiMH batteries
Micro USB cable
Technical Parameters
Model
Range (m)
Accuracy (mm)
Single measurement
Continuous measurement
Area measurement
Volume measurement
Direct Pythagoras
Indirect Pythagoras ①
Indirect Pythagoras ②
Addition/Subtraction
Auto horizontal measurement
Auto vertical measurement
Display type
Measurement reference
Measurement unit
Data logging
button to
button to measure
button to measure
button
button to measure
Quantity
Accessories
3
User manual
1
1
Pouch
1
LM50G
LM70G
LM100G
50m
70m
100m
-5
± (2.0mm+5x10 D)
2.4-inch EBTN screen
Front/Middle/Rear reference
m/ft/in/ft+in
20 groups
Auto power off
Laser class
Laser type
Battery type
Operating temperature
Interface type
Size (mm)
Weight (including batteries)
1. Range
The range data is based on the rear reference (default); the maximum range may vary
depending on the model version, and the actual range is shown on the product packaging.
2. Accuracy ("D" represents the measured length)
Under good measurement conditions (good measurement surface/room temperature/
indoor lighting, etc.): up to the rated range.
Under poor measurement conditions (too much light, weak reflection on the surface of
the measured object or large temperature difference, etc.): the error may increase.
Tip: Use a reflector or a good reflective surface in the case of poor daylight or target
reflection.
3. In the ideal state, the short distance accuracy can be up to 1mm
(Ideal state refers to constant speed (speed < 1m/s) and flat contact surface; short
distance means <1.5m)
4. Angle Error
0.1° is the error caused by the temperature, D is +/-0~45°.
For example, the 0 degree error is +/-0.3° at room temperature, the 45 degrees error is
+/-0.85° at non-room temperature.
VI. Fault Code – Problems and Solutions
All information is displayed in code or "Error". The following shows the codes and their
explanations and the corresponding solutions:
Code
Problems
204
Calculation error
Low battery
220
The reflected light received
255
is weak, or the measurement
time is too long
The received signal
256
is too strong
Over range
261
500
Hardware malfunction
3 minutes without operation
Class 2
505-515nm, <1mW
3 AAA rechargeable batteries (1.2V, NiMH)
0°C ~ 40°C (32°F ~ 104°F)
Micro USB interface (for charging)
59 x 28 x 137
170g
Solutions
Follow the instructions and operate again
Please replace the batteries or charge them
Please improve the reflective surface
(use a reflector, white paper, etc.)
Please improve the reflective surface
(use a reflector, or do not aim at strong light)
Please measure within the range
If it still appears after the meter has been
turned on/off multiple times, please contact
your dealer