Removing metal grease filter
Open the lock on the underside of the appliance and remove
1.
the metal grease filters from the retainer.
Note: Grease may accumulate in the bottom of the metal
grease filter. Hold the metal grease filter level, otherwise
grease will drip out.
Clean the metal grease filter.
2.
After removing the filters, clean the inside of the appliance.
3.
Clean the filter cover.
4.
Installing the metal mesh grease filter
Insert the metal grease filters with the lock to the front.
1.
Insert the metal grease filters on the underside of the
appliance.
Fold the metal grease filters inwards, locking them in place.
2.
Press and hold the
button for more than three seconds.
#
3.
The saturation indicator is reset.

Trouble shooting

Malfunctions often have simple explanations. Please read the
following notes before calling the after-sales service.
:
Risk of electric shock!
Incorrect repairs are dangerous. Repairs may only be carried
out and damaged power cables replaced by one of our trained
after-sales technicians. If the appliance is defective, unplug the
appliance from the mains or switch off the circuit breaker in the
fuse box. Contact the after-sales service.
Malfunction table
Problem
Possible cause Solution
The appliance
The plug is not
does not work
plugged in.
Power cut
Faulty fuse
8
Connect the appliance to
the electricity supply
Check whether other
kitchen appliances are
working
Check in the fuse box to
make sure that the fuse for
the appliance is OK
Changing the activated charcoal filter (only in
circulating-air mode)
In order to guarantee efficient odour filtration, the filter must be
serviced regularly.
The activated charcoal filters must be replaced at least every
4 months.
Notes
The activated charcoal filters are not included in the delivery.
The activated charcoal filters can be obtained from specialist
retailers, from our after-sales service or from the Online Shop.
The activated charcoal filters cannot be cleaned or
reactivated.
Removing the activated charcoal filter
To remove the metal grease filter, see above.
1.
Undo the screw connections on the retainer.
2.
Fold the retainer down and remove it.
3.
Fitting the activated charcoal filter
Slide the new activated charcoal filter into the retainer.
1.
Slide the wire into the retainer.
2.
Insert the retainer into the extractor hood.
3.
Close the screw connections on the retainer.
4.
To fit the metal grease filter, see above.
5.
Press and hold the
button until the saturation indicator no
#
6.
longer flashes.
The saturation indicator is reset.
The button illu-
The control unit
mination does
is faulty.
not work.
The lighting
The bulbs are
does not work.
faulty.
The grease or
or
flashes
ƒ
activated char-
in the display
coal filter is sat-
urated.
The grease and
or
ƒ
flashes
activated char-
in the display
coal filters are
saturated.
The ambient
flashes in the
£
temperature of
display
the display
panel is above
the tempera-
ture alarm limit.
--------
¨
©
Call the after­sales service.
For information on chang-
ing the bulbs, see the
"Replacing Bulbs" section.
Clean the filter – see the
section "Cleaning and main-
tenance".
Clean the filter – see the
section "Cleaning and main-
tenance".
Switch off the temperature
alarm – see the section
"Temperature alarm limit".