Series 5000 Single Row Pole Top
with SolarMount
Installation Manual 501.5
U.S. Des. Patent No. D496,248S. Other patents pending.
Parts List
(Parts are illustrated in exploded views, pp. 2–4.)
Part
Channel
Bracket, left
Bracket, right
SolarMount standard rail, drilled
U-bolt,
3
∕
˝
8
Hex head bolt,
3
∕
˝
8
Flange nut,
3
∕
˝
8
Self tapping screw, no.10 zinc
Module clip
Module bolt, ¼˝
Flat washer, ¼˝
Flange nut, ¼˝
* Per module to be mounted. Series 5000 racks include module hardware to
mount 1 or 2 modules, depending on the model number.
A HILTI GROUP COMPANY
See www.unirac.com for your nearest Unirac distributor.
Unirac welcomes input concerning the accuracy and user-friendliness of this publication. Please write to publications@unirac.com.
Rails
®
Thank you for purchasing a Unirac. Please read these
guidelines completely before proceeding.
This rack is intended for a 2.5-inch (65 mm) Schedule 40
steel pole, outside diameter 2.875 inches (73.0 mm). For
larger diameter poles, Unirac can fill special orders for
larger U-bolts.
The installer is solely responsible for:
• complying with all applicable building codes, in-
cluding any that supercede these instructions;
• pole installation appropriate to local wind and soil
conditions;
• using only Unirac parts and installer-supplied parts
as specified by Unirac (substitution of parts will
void the warranty);
• installing all electrical aspects of the PV array.
Wrench
Qty
size
1
1
1
2
2
8
9
∕
˝
16
4
9
∕
˝
16
2
4*
4*
7
∕
˝
16
4*
4*
7
∕
˝
16
R
Stainless steel hardware can seize up,
a process called galling. To significantly
reduce its likelihood, (1) apply lubricant
to bolts, preferably an anti-seize lubricant, avail-
able at auto parts stores, (2) shade hardware
prior to installation, and (3) avoid spinning on
nuts at high speed. See Installation Supplement
910, Galling and Its Prevention, at www.Unirac.
com.