SERVICE MANUAL
Model: HRF-628AF6/IF6

5-5. Self-testing function

1.Force start: Under locked mode, press Set-->Ref.Temp-->OK-->Frz.Temp"(A→D→B→C→A) one by
one within 5 sec. then press "Set",and the REF and RFZ display icon will display T1,T1)
2.Forced defrost : Keep the current state ,and press "Set" ,T2 will be present, then enter forced
defrost mode.
3.Quit:
Keep the current state, press "Set" ,then will be present T3→T4→back to normal display
control,and escape from test mode.
MODE
WORKING CONDITION
1)R and F display areas:T1、T1;
2)Compressor start work;
3)Freezer FAN work with high votage;
Force start
Cooling FAN work with high votage;
4)defrost heater off;
5)REF air damper open;
1)R and F display areas:T2、T2;
2)Enter defrost mode:
compressor OFF
Freezer /Cooloing FAN OFF
Forced
Defrost heater work,
defrost
if the D-SNR ≥ 7℃,D HTR work 10 sec and then quit test 2 mode;
if the D-SNR<7℃,D HTR will keep working until the D-SNR ≥ 7℃, and then quit test 2 mode;
3)REF air damper keep close
Keep the current state, press "Set" ,then will be present T3→T4→back
Quit
to normal display control,and escape from test mode.
Issue 2013-04-07