White OMS User Manual

Atex instruction

Advertisement

Quick Links

User Manual
ATEX instruction for OMS

Advertisement

Table of Contents
loading

Summary of Contents for White OMS

  • Page 1 User Manual ATEX instruction for OMS...
  • Page 3: Table Of Contents

    Filtering................................13 Painting of the motor............................13 Chapter 3: Installation, operation and maintenance........... 15 Installation................................16 Installation of OMS motor to the system....................16 Hydraulic connections for OMS motors....................17 Operation................................17 Pre start up controls for OMS motors..................... 17 Start up..............................18 Maintenance................................
  • Page 5: Chapter 1: Introduction

    Chapter Introduction Topics: General information • Intended use •...
  • Page 6: General Information

    The motors fulfill the explosion requirements with the Directive 2014/34/EU for the category shown on the name plate. The OMS motors have an identifying name plate. The name plate provides essential information and specification for correct and safe use. This identifying plate has to be maintained so that the data can be clearly read; consequently, a periodic cleaning of the plate is required.
  • Page 7 ATEX Certified Orbital Motors | Introduction | 7 Figure 1: Example label only Key to label image: 1. CE Conformity marking 2. EU marking (per 2014/34/EU) - Directive part Description EU Marking CE conformity marking Explosion protection marking Equipment group Equipment Category 2G / 2D 3.
  • Page 8: Maximum Surface Temperature For Oms

    Example of item 9: N95123094 Manufacturing location (N = Nordborg) Year 2019 Week 51 Tuesday (1 = Monday) 3094 Consecutive number Maximum surface temperature for OMS Classification of maximum surface temperatures for Group II equipment Temperature class Maximum surface temperature °C [°F] [392]...
  • Page 9 ATEX Certified Orbital Motors | Introduction | 9 Maximum surface temperature – Dusty environment (Group III) Table 2: OMS motors - Maximum surface temperatures Maximum oil Maximum ambient temperature temperature ≤ 20 °C [68 °F] ≤ 40 °C [104 °F] ≤...
  • Page 11: Chapter 2: Technical Information

    Chapter Technical information Topics: Product description • Technical specification for OMS • motors Oil types / Operating fluids • Temperature and viscosity • Filtering • Painting of the motor •...
  • Page 12: Product Description

    The operating principle of the motor is based on an internal gear design, consisting of a fixed external gear reaching against an internal gear through which the output torque and speed are transmitted. The distributor valve in OMS motors is of the disc valve design which is driven synchronously by the internal gear through a cardan shaft ensuring that the individual chambers of the motor are filled and emptied precisely.
  • Page 13: Ambient Temperature

    Oil temperature Maximum oil temperature depends on the requested ATEX class needed. See Maximum surface temperature for OMS on page 8. Under normal operating conditions it is recommended to keep the temperature in the range of 30 °C [86 °F] to 60 °C [140 °F].
  • Page 15: Chapter 3: Installation, Operation And Maintenance

    Chapter Installation, operation and maintenance Topics: This section is intended for personnel assigned to install the motor on the machine or system for which the unit has been purchased. Therefore the Installation • importance of this section is emphasized since the optimum operation of Operation •...
  • Page 16: Installation

    ATEX Certified Orbital Motors | Installation, operation and maintenance | 16 Installation Installation of OMS motor to the system When assembling the motor in the machine/system it is the builder’s responsibility that the parts used conform to the ATEX directive and that the components are assembled and running according to the operational data/design found in product data sheets and instructions.
  • Page 17: Hydraulic Connections For Oms Motors

    Operation The purpose of this section is to indicate the necessary procedures to perform the motor start up. Pre start up controls for OMS motors Before performing the first motor start up, the following points have to be checked: •...
  • Page 18: Start Up

    ATEX Certified Orbital Motors | Installation, operation and maintenance | 18 • To avoid contamination, plastic plugs in connection ports must not be removed until just before connections are made. • Make sure the motor hydraulic connections allow the motor to rotate in the desired direction. For motors with standard direction of rotation: •...
  • Page 19: Maintenance

    For installation in zones 21 and 22 the user has to adopt a scheduled periodic clearing plan of the motor surfaces and recesses to prevent more than 5mm thickness of dust deposits. Service and repair of OMS motors In case a service or repair intervention on the motor is required, it has to be performed according to the information shown in the respective Repair Instructions.
  • Page 20 Unintended machine movement Warning: Unintended movement of the machine or mechanism may cause injury to the technician or bystanders. To protect against unintended movement, secure the machine or disable/disconnect the mechanism while servicing. Follow the manufacturers instructions for securing the machine. Personal safety Warning: Protect yourself from injury.
  • Page 21: Chapter 4: Declaration

    Chapter Declaration EU Declaration of Conformity to be added by White.

Table of Contents