SELECT THE BEST LOCATION

1
 
If an awning is built over the unit to prevent direct sunlight or rain, be careful that heat radiation from the condenser is not obstructed.
 
Avoid installations in areas where the ambient temperature may drop below -28°C.
 
Keep the spaces indicated by arrows from wall, ceiling, fence or other obstacles.
 
Do not place any obstacles which may cause a short circuit of the discharged air.
 
If outdoor unit installed near sea, region with high content of sulphur or oily location (e.g. machinary oil, etc.), it lifespan maybe shorten.
 
When installing the product in a place where it will be affected by typhoon or strong wind such as wind blowing between
buildings, including the rooftop of a building and a place where there is no building in surroundings, fi x the product with an
overturn prevention wire, etc. (Overturn prevention fi tting model number: K-KYZP15C)
 
If piping length is over 10 m, additional refrigerant should be added as shown in the table.
Piping size
Gas
Liquid
ø15.88mm (5/8") ø9.52mm (3/8")
Example:
If piping length is 30m, the quantity of additional refrigerant should be 1000g. [(30-10)m x 50 g/m = 1000g]
GWP (R410A) = 2088
INSTALL THE OUTDOOR UNIT
2

INSTALLATION DIAGRAM

DIMENSION DIAGRAM

Rated
Max.
Min. Piping
Length
Elevation
Length
(m)
(m)
(m)
7
20
3
It is advisable to avoid more than 2 blockage directions. For better ventilation & multiple-outdoor installation,
please consult authorized dealer/specialist.
This illustration is for explanation purposes only.
1284
318.5
152
980
Max. Piping
Additional
Length
Refrigerant
(m)
(g/m)
30
50
Vinyl tape (Wide)
Saddle
Indoor/Outdoor connecting cable
2
6-CORE WIRE min 1.5mm
Type designation 60245 IEC 57 or heavier cord
ø9.52mm (3/8") Liquid refrigerant piping
ø15.88mm (5/8") Gas refrigerant piping
59
322
39
148
157
152
189
28
31
20
(Unit : mm)