DIGITAL STILL CAMERA DSC-RX100M4 SERVICE MANUAL (LEVEL 2) 1st Edition...
Page 2
Ce manual est destiné uniquement aux personnes compétentes en charge de l’entretien. Afin de réduire les risques de décharge électrique, d’incendie ou de blessure n’effectuer que les réparations indiquées dans le mode d’emploi à moins d’être qualifié pour en effectuer d’autres. Pour toute réparation faire appel à une personne compétente uniquement. DSC-RX100M4...
Page 3
Be sure to keep your PC used for service and checking of this 修理時に使用するパソコンは,ウィルス検出ソフトが常にアッ プデートを行っているパソコンを使用してください。もし,修 unit always updated with the latest version of your anti-virus software. In case a virus affected unit was found during service, 理を行うセット,もしくはパソコンがウィルスに感染している 事が判明した場合は,ソニーグループ内は社内技術相談窓口に, contact your Service Headquarters. 特約店様は特約店様専用電話窓口(修理窓口)にご相談くださ い。 DSC-RX100M4...
Page 4
CRITIQUES POUR LA SÉCURITÉ DE FONCTIONNEMENT. NE COMPONENTS WITH SONY PARTS WHOSE PART NUMBERS REMPLACER CES COMPOSANTS QUE PAR DES PIÈCES SONY APPEAR AS SHOWN IN THIS MANUAL OR IN SUPPLEMENTS DONT LES NUMÉROS SONT DONNÉS DANS CE MANUEL OU PUBLISHED BY SONY.
• Help Guide (Web manual) Refer to “Help Guide” for in-depth instructions on the many functions of the camera. • Adjust Manual (Available on request) The adjustment software is necessary for adjustment and various checking of this unit for the service. DSC-RX100M4...
Page 13
Lens Ring Block Assy Section..................4-16 DSC-RX100M4...
Turn power off and turn power on again. When this error is (Cannot initialize focus) not cleared, the focus control signal for the lens block may be faulty. Check whether this error is due to the lens or the board. Replace the faulty lens or board. Continued DSC-RX100M4...
Page 18
STEADYSHOT turned ON that the steadyshot functions appropriately in the handheld operation. After check, be sure to perform “1-2. Process after Fixing Flash Error”. Function of this code is not provided in this unit. DSC-RX100M4...
Page 19
Replace the board that contains this peripheral circuit. Electronic compass hardware error The peripheral circuit of the electronic compass may be (GPS hardware error) faulty. Replace the board that contains this peripheral circuit. Function of this code is not provided in this unit. DSC-RX100M4...
When “FLASH error” (Self-diagnosis Code E:91:01) occurs, to prevent any abnormal situation caused by high voltage, setting of the flash is changed automatically to disabling charge and flash setting. After fixing, this setting needs to be deactivated. Method of initializing the flash error code: Reset Flash Error using the Flash Error Repair Tool Ver_[].[].exe. DSC-RX100M4...
• The proper way to disconnect a connector is to grab the connector instead of the wires. If you pull on the wires, they might be broken. • The proper way to connect a connector is to grab the connector instead of the wires. If you push on the wires, they might be broken. DSC-RX100M4...
In order to prevent an electric shock, wrap insulating tape completely around the resistor and its leads. Resistor with a rated value of approximately 1 k /1 W (Part No. 1-215-869-11). Small clip Small clip Wrap insulating tape completely around the resistor and its leads. DSC-RX100M4...
Procedure of the MAC address update: Note Perform the below operations after all work has been done. Start the Adjust Manual in the Adjust Station and execute the “Wireless LAN Setting (MAC Address)” on the ADJUST tab. Operate the unit to initialize of SSID/PW. DSC-RX100M4...
Page 24
After the replacement and repair, the MAC address is changed, and thus the re-setting for connection devices is required. Accordingly, download the Flyer of WLAN Reset (Flyer of WLAN Reset_9834752[][].pdf) and print out it, and attach it to the set when returning the set to customer. DSC-RX100M4...
The thickness of the Spacer Plate to be loaded is displayed. Select the Spacer Plate according to the instructions on the screen and mount the imager board. 2-3-2. Adjustment after Replacing the Lens Perform LOAD from “Lens data carry” on the ADJUST tab in the Adjust manual. DSC-RX100M4...
If any Spacer Plate is lost or their previous positions are not sure, repeatedly take a photo and check that there is no local defocus. Selecting appropriate Spacer Plates is needed. When the lens is replaced Refer to “2-3. Notes on Replacing the Lens” for select Spacer Plates and install them to the new lens. DSC-RX100M4...
Turn on the power of the unit and enable the Wi-Fi function. (Upon completion of the preparation for Wi-Fi connection, the password for Wi-Fi connection is displayed.) Confirm on the PC or the smartphone that the unit is detected as a connectable wireless network. DSC-RX100M4...
Start the Adjust Manual in the Adjust Station and execute the “Angular velocity sensor sensitivity adj” on the ADJUST tab. Note The sensitivity of the angular velocity sensor is indicated only on the repairing board, but is not indicated on mass production boards. DSC-RX100M4...
Make a jig as shown below by bending fine wire. Approx. 5 mm Approx. 0.7 mm Approx. 30 mm Procedure: Depress the viewfinder pop-up switch to pop up the EVF. Draw the VF eyepiece block. Holes Viewfinder pop-up switch DSC-RX100M4...
Page 30
Insert both ends of the jig into the holes of the VF eyepiece block, gently hold the jig, and then pull out the VF eyepiece block while pushing the internal bosses. Note Do not scratch the main body with the jig. Note : Be careful not to touch the grease applied to below parts. Grease VF eyepiece block 2-10 DSC-RX100M4...
It is the software to adjust and check digital cameras and camcorders for service. The installer of the Adjust Manual and the installation manual are attached, be sure to confirm the contents of them. Note Be sure to install Adjust Station first. DSC-RX100M4...
Adjust Station から Adjust Manual を起動し, ADJUST タブにある“PRODUCT ID & USB SERIAL No. INPUT”を実施してください。 2-2-4. MAC アドレスの更新 Wi-Fi 搭載基板を交換した場合,または,メイン IC (CPU) が搭載されている基板を交換した場合は, MAC アドレスを更新する必要があります。 MAC アドレス更新方法: 注意 下記の操作は全ての作業を実施した後に行ってください。 Adjust Station から Adjust Manual を起動し, ADJUST タブにある“Wireless LAN Setting (MAC Address)”を実施する。 本機を操作し, SSID・PW リセットを行う。 DSC-RX100M4...
Ref. No. Main Frame Assy Section #247 (Note) Claws Claws #215 #247 #196 (Note) #247 (Note) Note This screw can not be reused. Discard the screw removed once in servicing. Instead, use a new screw. このねじは再利用することができません。 サービス対応時に一度でも外した場合は新品のねじと交換 してください。 DSC-RX100M4...
Page 52
(3) While lifting the A portion of the USB Lid and HDMI Lid slightly with tweezers or the like, pull the USB Lid and HDMI Lid in the direction of arrow to disengage it. Tweezers HDMI Lid (1) Tilt the LCD. DSC-RX100M4...
Note 1 Use this to cut or splice so that it becomes the designated size. 指定のサイズになるように形状を加工して使用してください。 Note 2 This screw can not be reused. Discard the screw removed once in servicing. Instead, use a new screw. このねじは再利用することができません。 サービス対応時に一度でも外した場合は新品のねじと交換 してください。 DSC-RX100M4...
Page 54
Connect the shot jig to terminals of flash capacitor to discharge the capacitors. (Part code: 1-215-869-11) Main Frame Assy Section Disassembly Places [1]: #247 x 1 → #247 x 1 → Disconnect the Flexible Board {1} Back View Left View #247 #247 DSC-RX100M4...
Page 55
[2]: Tilt the LCD {2} → #239 x 2 Back View #239 DSC-RX100M4...
Do not hold the following part. Hold the Lens Block at the center of both sides. G10 lens *Very weak Hold here. Zoom motor, Lens barrier Gear B *Very weak *Very weak Note 2 BETR Radiation Sheet Assy includes two kind of sheets Ref.102 and Ref.161. BETR Radiation Sheet Assy には, Ref.102とRef.161の2種類の シートが含まれています。 DSC-RX100M4...
Page 57
[1]: #45 x 1 Back View [3]: Refer to “Removal of SY-1052 Board” [5]: Disconnect the Flexible cables → #209 x 1 → Detach the ST Flexible Base {5}-1 Back View Back View Flexible Board Flexible Boards {5}-1 #209 DSC-RX100M4...
Page 58
Removal of SY-1052 Board Disconnect the 4 flexible boards from the connectors on the SY-1052 Board. Connectors SY-1052 Board Connectors Remove the two screws (#247). #247 Disengage the three claws. Claws 4-10 DSC-RX100M4...
Page 59
Detach the Strap (R) from two terminals on the SY-1052 Board. Strap (R) Claws SY-1052 Board Disconnect the two flexible boards from the connectors on the SY-1052 Board. Connectors SY-1052 Board 4-11 DSC-RX100M4...
EVF Block Assy Section #247 #312 (Note 3) #312 #312 SP901 Note 1 This part can not be reused. Discard the part removed once in servicing. Instead, use a new part. この部品は再利用することができません。 サービス対応時に一度でも外した場合は新品の部品と交換 してください。 Note 2 BETR Radiation Sheet Assy includes two kind of sheets Ref.102 and Ref.161. BETR Radiation Sheet Assy には, Ref.102とRef.161の2種類の シートが含まれています。 4-12 DSC-RX100M4...
Page 61
Instead, use a new screw. このねじは再利用することができません。 サービス対応時に一度でも外した場合は新品のねじと交換 してください。 MS Board and BTH Assy Section Disassembly Places [1]: Pop-up the EVF unit {1}-1 → #312 x 3 {1}-1 #312 #312 [3]: #247 x 2 Back View #247 #247 4-13 DSC-RX100M4...
(Including FP-2234 Flexible Board) #209 When assembling, #280 #312 adjust the position. #239 (Note) #239 (Note) Note This screw can not be reused. Discard the screw removed once in servicing. Instead, use a new screw. このねじは再利用することができません。 サービス対応時に一度でも外した場合は新品のねじと交換 してください。 4-14 DSC-RX100M4...
Page 63
[2]: #239 x 2 Bottom View #239 [3]: Pop-up the Flash {3}-1 → #280 x 2 Back View Back View {3}-1 #280 Notes on Assembling the ST Block Assy Arranging the SE-1010 Flexible Board Mountain fold Valley fold SE-1010 Flexible Board 4-15 DSC-RX100M4...
#209 #209 Notes on Assembling the Lens Ring Block Assy Assembling the Lens Ring Block Set the Lens Ring so that its character part faces in the same direction as the XX mark on the Manual Ring Block. 4-16 DSC-RX100M4...
Page 65
Attach the Lens Ring while aligning its concave with the convex of the Manual Ring as shown in the figure. Lens Ring Convex XX mark Manual Ring Block Turn the Lens Ring approx. 20 degrees clockwise to attach it. Lens Ring 4-17 DSC-RX100M4...
“EVF Block Assy Section” on exploded view for Ref. No. #247 #312 (Note) #312 #312 C901 Note This screw can not be reused. Discard the screw removed once in servicing. Instead, use a new screw. このねじは再利用することができません。 サービス対応時に一度でも外した場合は新品のねじと交換 してください。 4-18 DSC-RX100M4...
Page 67
Notes on Assembling the EVF Block Assy Arranging the VF Block Assy VF Block Assy Mountain fold Valley fold Arranging the ST-1032 Flexible Board ST-1032 Flexible Board Mountain fold Valley fold 4-19 DSC-RX100M4...
Note 1 Use this to cut or splice so that it becomes the designated size. 指定のサイズになるように形状を加工して使用してください。 Note 3 This screw can not be reused. Discard the screw removed once in servicing. Instead, use a new screw. このねじは再利用することができません。 サービス対応時に一度でも外した場合は新品のねじと交換 してください。 4-20 DSC-RX100M4...
4-2-9. Lens Block Section • Refer to “Lens Block Section” on exploded view for Ref. No. #302 (Note 1) #258 (including IC1003 (CMOS imager) and #258 CD-1006A flexible board) #176 (Claws) (Claw) (Claws) (Note 2) 4-21 DSC-RX100M4...
Page 70
G10 lens *Very weak Hold here. Zoom motor, Lens barrier Gear B *Very weak *Very weak Note 2 Do not reuse these Parts because their adhesive force decreases when they are removed once. これらの部品は一度剥がすと粘着力が弱くなるため, 再利用は しないでください。 4-22 DSC-RX100M4...
Barrier Assy Claws Installation Fit the four claws while inserting the barrier lever into the hole and attach the Barrier Block Assy. Barrier Block Assy Claws Barrier Lever Claws Hole Peel off the release paper of the Barrier Tape. 4-23 DSC-RX100M4...
Page 72
Install the Ornamental Ring (A) and press it lightly. Ornamental Ring (A) Barrier Tapes Barrier Tapes Barrier Block Assy 4-24 DSC-RX100M4...
Seal Rubber Spacer Plate CD-1006A Flexible Board Spacer Plates Remove the FG Retainer. FG Retainer Claw Pull out the FG-PI of front side, and then pull out the FG-PI of rear side. FG-PI (rear side) Hook FG-PI (front side) 4-25 DSC-RX100M4...
Page 74
Disconnect the F Flexible Board from the connector of the LF-2091 Flexible Board. LF-2091 Flexible Board F Flexible Board Connector Stationary Tube Remove the LF-2091 Flexible Board from the hook of the Rear Tube Mirror Block Assy. Hook 4-26 DSC-RX100M4...
Page 75
12. Disconnect the two flexible boards (SS and SH) from the connectors of the LF-2091 Flexible Board. SS flexible board SH flexible board 13. Remove the connector part of the LF-2091 Flexible Board from the holes of the Stationary Tube. Holes Holes 4-27 DSC-RX100M4...
Page 76
*) Use a Lubricating Block Assy (B) that was not installed in the unit. Lubricating Block Assy (B) 17. Pull out the two flexible boards (SS and SH) from the Stationary Tube. SS flexible board Stationary Tube SH flexible board 4-28 DSC-RX100M4...
Page 77
20. Turn the Straight Tube Block Assy counterclockwise and remove it from the 1st/2nd/3rd group assy. Straight Tube Block Assy Straight Tube 1st/2nd/3rd group assy Block Assy 21. Remove the 1 Group Frame Block Assy from the 2nd/3rd group assy. 1 Group Frame Block Assy 2nd/3rd group assy 4-29 DSC-RX100M4...
Page 78
1st/2nd/3rd group assy After turning the Straight Tube Block Assy counterclockwise about eight degrees to fully install it, turn the Straight Tube Block Assy clockwise to the maximum extent to fit the bayonet. About 8° Straight Tube Block Assy 4-30 DSC-RX100M4...
Page 79
*) Use a Lubricating Block Assy (B) that was not installed in the unit. Lubricating Block Assy (B) Pass the two flexible boards through the holes in the Stationary Tube. SS flexible board Stationary Tube SH flexible board 4-31 DSC-RX100M4...
Page 80
Attach the Rear Tube Mirror Block Assy and tighten five screws in numerical order in the following figure. Rear Tube Mirror Block Assy 10. Install the connector part of the LF-2091 Flexible Board to the holes of the Stationary Tube. Holes Holes 4-32 DSC-RX100M4...
Page 81
Focus FPC Retainer 13. Install the LF-2091 Flexible Board to the hook and the boss of the Stationary Tube. Boss Hook 14. Install the LF-2091 Flexible Board to the hook of the Rear Tube Mirror Block Assy. Hook 4-33 DSC-RX100M4...
Page 82
17. Install the Reset PI on the LF-2091 Flexible Board to the Rear Tube Mirror Block Assy. Reset PI 18. Install the Z Seal. Z Seal 19. Install the FG-PI of rear side, and then install the FG-PI of front side. FG-PI (rear side) Hook FG-PI (front side) 4-34 DSC-RX100M4...
Page 83
21. Put on the Spacer Plates, and install the CD-1006A Flexible Board and tighten three screws in numerical order in the following figure. Seal Rubber Spacer Plate CD-1006A Flexible Board Spacer Plates 22. Stick a new Insulating Sheet (ST3). Insulating Sheet (ST3) 4-35 DSC-RX100M4...
Note 2 or Q'ty Part No. SP Description 4-479-103-01 SHEET (LCD), LIGHT INTERCEPTION This repair part supplied by Sony differ from those used for LCD901 1-811-695-11 PANEL MODULE (PE5-BJD) the unit. This is because of part commonality. ソニーから供給する補修用部品は, セッ トに使われているもの...