28/233
Bosch Rexroth AG | Electric Drives
General Operation and Visualization
5.2
Basic NC Screen
5.2.1
Overview
5.2.2

Position Display

Display Contents

Column Selection
Rexroth IndraMotion MTX 09VRS | Application Description
and Controls
Different screens with window splits are available for the NC screen of the Re‐
xroth IndraMotion MTX NC Screen. The contents of these partial windows can
be provided by user-defined displays.
By default, the Bosch Rexroth process displays are located here. These can
be freely configured in IndraWorks Engineering and adapted to the specific
machine configurations.
The corresponding user rights are necessary for configuration.
The Bosch Rexroth process displays have both machine-dependent and pure
interface-related parameters for individual configuration.
Machine parameters are set in the NC configurator in IndraWorks Engi‐
neering.
Interface parameters are set in the options dialog box of the relevant dis‐
plays in IndraWorks Operation.
You can find further information regarding the configuration of NC
screens in the documentation "Rexroth IndraMotion MTX Startup".
The position display is used to display axis data. A maximum of 8 axes per
channel is supported.
Fig.5-2:
Position display
The columns and variants are selected using the variant editor of the options
dialog box. Variants with the following column data can be defined here.
Target position
End position
Distance to go
Program
Lag
Actual position
$ Target position (= channel position during system axis coupling)
Axis velocity (only ACS)
Axis target speed (only ACS; available only for asynchronous, endlessly
turning round axes, otherwise value = "0")