Technical Specifications - Airstream ITA-6 User Manual

Table of Contents

Advertisement

TECHNICAL SPECIFICATIONS

Supply: - 115/230 VAC (- 18%, + 8%), 50/60 Hz, overload and overvolt-
age protection fuse F6-1A fast blow.
- 12 VDC for AC back-up supply, can activate the inlet and alarm if sup-
plied with DC back-up voltage.
Power unit: 50/60 Hz, 30 VDC, 5A motor output, fuse F1-5A slow blow.
Alarm: ON-OFFoutput, 115/230 VAC, 50/60 Hz, 30 VDC, 3A, fuse F4-3A
slow blow.
Probes: Low voltage ( < 5V), isolated from the supply. Operating range:
-40.0° to 120.0°F(-40.0° to 49°C). Accuracy: 1.8
and 95
F (5° and 35°C).
o
Enclosure: ABS, humidity and dust-tight.
The room temperature where the controller is located MUST
ALWAYS REMAIN BETWEEN 32
32
ITA-6 rev.02
AND 104
o
For indoor use.
F (1°C) between 41
o
F (0
AND 40
o
o
o
o
C).