4.
In approximately 15 seconds, LEDs above the HS ETH port will flash green (left flash, right flash, left flash). Continue to hold the reset pin.
5.
In approximately 15 more seconds the LEDs above the HS ETH port will flash green twice. This indicates the CMS is booting from the
main firmware, and you may release the Restore button

Reseat Board

If the CMS does not power on when the projector main power is applied, or if an undiagnosable error in color output during playback
should occur, it may be necessary to reseat the CMS-5000 in the IMB slot of the projector. Note that this will break marriage with the
projector. Do not proceed unless you are familiar with the projector's marriage procedure.
1.
Attach adequate ESD protection to protect the electronics.
2.
Shutdown and disconnect power from the projector.
3.
Recommended: Take a photograph of all connections before disconnecting the CMS-5000.
4.
Open any necessary side panels of the projector to expose the entire CMS-5000 faceplate.
5.
Disconnect any cables attached to the CMS-5000.
6.
Unscrew the two cage screws at the edges of the faceplate, if included (NEC and Barco models).
7.
Pull directly out on the CMS-5000 faceplate to remove the card from the slot.
8.
Inspect the edge connector for damage.
9.
Reverse these procedures to reinstall, making sure to firmly seat the CMS in the projector slot.
Once the CMS is reinstalled, reconnect and power on the projector. Perform the marriage procedure to return the CMS-5000 to an
operational state. See section LED Modes to determine the status of the CMS based on state of the front panel LEDs.

References

Quick Start Guide (TD-001577)

Basic information about CMS intallation and setup can be found in the CMS-5000 Quick Start Guide that is shipped with the CMS and
available at QSC.com.

Security Guide (TD-001589)

Information on default user accounts and passwords can be found in the CMS-5000 Security Guide that is shipped with the CMS or
contact QSC Technical Services.

Application Programmer's Interface (TD-001592)

Information on the API that allows third-party software to control the CMS is provided by the CMS-5000 Application Programmer's
Interface. Contact QSC Technical Services if you are interested in implementing the API in your software.