MINIMUM CLEARANCE TO COMBUSTIBLE ENCLOSURES

THE FRONT OF THE APPLIANCE MUST BE FINISHED WITH ANY NON-COMBUSTIBLE MATERIALS
SUCH AS BRICK, MARBLE, GRANITE, ETC., PROVIDED THAT THESE MATERIALS DO NOT COVER
THE STEEL STUD FRAMING KITS WITH CEMENT BOARD PROVIDED MUST BE INSTALLED.
IMPORTANT: The HDX52-2 requires a minimum inside enclosure height of 88" (223.5cm), measured from the
bottom of the appliance. For temperature requirements, this area must be left unobstructed. It is recommend-
ed that the enclosure be ventilated at the top and bottom to circulate the air.
NOTE: JOINT COMPOUNDS AND TAPES
THAT ARE RESILIENT TO HEAT AND
CRACKING SHOULD BE USED WHEN
TAPING AND MUDDING SEAMS.
88"
223.5cm *
MINIMUM
ENCLOSURE
HEIGHT
TOP OF
FIREPLACE
OPENING
NON-COMBUSTIBLE
MATERIAL
** See venting section
!
RISK OF FIRE!
THE APPLIANCE OPENING.
COMBUSTIBLE
MATERIAL
STEEL STUD
FRAMING
13"
33cm
MINIMUM
41 7/8"
106.4cm
6"
152mm
MINIMUM
WARNING
TOP OF ENCLOSURE
11"
279mm
MINIMUM **
27
BRICK
4 1/2" 114mm
0" (0mm) IF NON-
COMBUSTIBLE FINISHING
IS USED SUCH AS BRICK
AND STONE
1 1/2"
38mm
71 1/2"
181.6cm
MINIMUM
PLUS RISE **