Fujitsu PRIMERGY RX100 S3 Service Supplement Manual page 30

Hide thumbs Also See for PRIMERGY RX100 S3:
Table of Contents

Advertisement

Replacing the system board
Figure 14: Removing the screws
Ê Remove the nine screws from the system board.
Ê Carefully lift the system board out of the chassis at a slight angle.
Ê Check the settings on the new system board (for a description see the
Technical Manual of the system board).
Ê Insert the system board by holding it at a slight angle.
V
CAUTION!
Never remove the system board by grapping the fixed heat sinks!
Don't damage the EMI springs to comply with applicable EMC regula-
tions and satisfy cooling requirements and fire protection measures.
Ê Lower the system board carefully into the chassis.
30
Service Supplement
Replacement routines
RX100 S3