Specifications
2.5.2
The system environment must allow sufficient air flow to limit maximum surface
temperatures as defined. MTBF can be affected by workload and operating
temperature. See Section 2.6 on page 11 for further details.
Min-Max Base Casting
Temperature
Humidity
Thermal Gradient
Humidity Gradient
Non-operating Temperature
Humidity
Thermal Gradient
Humidity Gradient
1
The system environment must allow sufficient air flow to limit maximum base casting temperatures as
defined in Figure 2-2 below.
8
Temperature and Humidity
0C to 65C on the base casting (see Figure 2-2 below)
1
5-95% RH non-condensing
37.7C (maximum wet bulb)
20C/hour (maximum)
20%/hour (maximum)
-40C to 70C on the base casting (see Figure 2-2 below)
5-95% RH non-condensing
35C (maximum wet bulb)
30C/hour (maximum)
20%/hour (maximum)