Temperature And Humidity - Western Digital Purple PR1200M Technical Reference Manual

Surveillance hard drives
Table of Contents

Advertisement

Specifications
2.5.2
The system environment must allow sufficient air flow to limit maximum surface
temperatures as defined. MTBF can be affected by workload and operating
temperature. See Section 2.6 on page 11 for further details.
Min-Max Base Casting
Temperature
Humidity
Thermal Gradient
Humidity Gradient
Non-operating Temperature
Humidity
Thermal Gradient
Humidity Gradient
1
The system environment must allow sufficient air flow to limit maximum base casting temperatures as
defined in Figure 2-2 below.
8

Temperature and Humidity

0C to 65C on the base casting (see Figure 2-2 below)
1
5-95% RH non-condensing
37.7C (maximum wet bulb)
20C/hour (maximum)
20%/hour (maximum)
-40C to 70C on the base casting (see Figure 2-2 below)
5-95% RH non-condensing
35C (maximum wet bulb)
30C/hour (maximum)
20%/hour (maximum)
RELEASED 5/4/17 (WD CONFIDENTIAL)
Operation
Non-Operation
WD Purple™ PR1200M
2679-800065-A03

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wd60purxWd60purzWd60evrx

Table of Contents