Diagnostic Codes Table - Chamberlain RSL12UL Installation Manual

Residential dc vehicular slide gate operator
Table of Contents

Advertisement

Diagnostic Codes Table

Some codes are saved in the code history and some are not. If a code is not saved it will briefly appear on the display as it occurs, then disappear.
LiftMaster System
Code
Meaning
31
Main control board has experienced an internal
failure.
34
Absolute Position Encoder Error, not getting
position information from encoder
35
Max-Run-Time Exceeded Error
36
Product ID Error
37
Product ID Failure
38
Hard Stop Limit (Arm 1)
40
Battery overvoltage
41
Battery overcurrent
42
No battery at boot up
43
Exit Loop Error
44
Shadow Loop Error
45
Interrupt Loop Error
46
Wireless edge battery low
50
Run-Distance Error
53
Brownout occurred
54
Wireless Second Operator Communication Error
Minimum number of monitored entrapment
60
protection devices not installed.
61
CLOSE EYE/INTERRUPT held more than 3 minutes
62
CLOSE EDGE held more than 3 minutes
63
OPEN EYE/EDGE held more than 3 minutes
64
CLOSE EYE/INTERRUPT held more than 3 minutes
65
CLOSE EYE/EDGE held more than 3 minutes
66
OPEN EYE/EDGE held more than 3 minutes
67
Wireless edge triggered more than 3 minutes
68
Wireless edge loss of monitoring
TROUBLESHOOTING
Installed System
Solution
Disconnect all power, wait 15 seconds, then reconnect power (reboot). If
issue continues, replace main control board.
Check APE assembly and wiring connections. Replace the APE assembly
if necessary.
Check for an obstruction, then reprogram the limits.
Was the control board just replaced? If so, erase limits, enter limit setup
mode and set limits. If not, disconnect all power, wait 15 seconds, then
reconnect power before changing product ID harness.
Unplug product ID harness then plug back in. Disconnect all power, wait
15 seconds, then reconnect power before replacing product ID harness.
Limit may be set too tightly against a non-resilient hard stop (re-adjust
limit). Operator may be at end of travel (re-adjust mounting).
Too much voltage on the battery. Check harness. Make sure there is NOT a
24V battery on a 12V system.
Possible short of the battery charge harness. Check harness. Make sure
you do NOT have a 12V battery on a 24V system.
Check battery connections and installation. Replace batteries if depleted to
less than 20V on a 24V system or less than 10V on a 12V system. Make
sure there is NOT a single 12V battery on a 24V system.
Failure or missing loop (SHORT or OPEN - LiftMaster Plug-in Loop
Detector only) Check loop wiring throughout connection. May be a short
in the loop, or an open connection in the loop.
Replace batteries in wireless edge.
The limits are less than the minimum requirement or longer than what
was learned. Check limit positions and proper switch function. Run-
distance can be re-learned by setting the handing again.
AC/DC board supply dipped below allowable level. Review power supply
and wiring. If rebooting, ensure enough time for discharge of power to
force a fresh boot.
Check the second operator for power. If OFF, restore power and try to run
the system. If powered, deactivate the wireless feature and then re-learn
the second operator.
Review monitored entrapment protection device connections. Slide gate
operators require a minimum of two external safety devices; one in the
close and one in the open direction.
Check wired input on main control board; check for alignment or
obstruction.
Check wired input on expansion board; check for alignment or
obstruction.
Check wired input for wiring issue or obstruction.
Check wireless edge inputs.
Informational
32
External Entrapment
Protection
Inherent Entrapment
Protection
Saved
NO
YES
YES
YES
YES
NO
YES
YES
YES
YES
YES
YES
YES
YES
NO
YES
YES
YES
YES

Hide quick links: