Main Menu List - Mitsubishi Electric Mr.SLIM PUZ-ZM200YKA Service Manual

Split-type, heat pump air conditioners
Hide thumbs Also See for Mr.SLIM PUZ-ZM200YKA:
Table of Contents

Advertisement

Main menu list

Main
Setting and display items
menu
Operation Vane · Louver · Vent.
(Lossnay)
High power *
3
Comfort Manual
vane angle
3D i-See sensor Use to set the following functions for 3D i-See sensor.
Bluetooth connection
ON/OFF timer *
Timer
Timer
Auto-Off
timer
Weekly timer *
OU silent mode *
Night setback *
Restriction Temp. range *
Energy
saving
Operation lock
Auto return *
Energy
saving
Schedule *
*
1
Clock setting is required.
*
2
1°C increments.
*
3
This function can only be set when certain outdoor units are connected.
OCH738
Use to set the vane angle.
• Select a desired vane setting from 5 different settings.
Use to turn ON/OFF the louver.
• Select a desired setting from "ON" and "OFF."
Use to set the amount of ventilation.
• Select a desired setting from "Off," "Low," and "High."
Use to reach the comfortable room temperature quickly.
• Units can be operated in the High-power mode for up to 30 minutes.
Use to fix each vane angle.
• Air distribution • Energy saving option • Seasonal airflow
Use to check the information about bluetooth connection between smartphone
and the remote controller.
1
Use to set the operation ON/OFF times.
• Time can be set in 5-minute increments.
Use to set the Auto-Off time.
• Time can be set to a value from 30 to 240 in 10-minute increments.
*
1,
2
Use to set the weekly operation ON/OFF times.
• Up to 8 operation patterns can be set for each day.
(Not valid when the ON/OFF timer is enabled.)
*
1,
3
Use to set the time periods in which priority is given to quiet operation of
outdoor units over temperature control. Set the Start/Stop times for each day
of the week.
•Select the desired silent level from "Normal," "Middle," and "Quiet."
1
Use to make Night setback settings.
• Select "Yes" to enable the setting, and "No" to disable the setting. The temperature
range and the start/stop times can be set.
2
Use to restrict the preset temperature range.
• Different temperature ranges can be set for different operation modes.
Use to lock selected functions.
• The locked functions cannot be operated.
2
Use to get the units to operate at the preset temperature after performing
energy saving operation for a specified time period.
• Time can be set to a value from 30 and 120 in 10-minute increments.
(This function will not be valid when the preset temperature ranges are restricted.)
1
Set the start/stop times to operate the units in the energy saving mode for
each day of the week, and set the energy saving rate.
• Up to 4 energy saving operation patterns can be set for each day.
• Time can be set in 5-minute increments.
• Energy saving rate can be set to a value from 0% or 50 to 90% in 10% increments.
Setting details
89

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr.slim puz-zm250ykaPuz-zm200yka.ukPuz-zm250yka.uk

Table of Contents