Napoleon B35NTL Installation And Operating Instructions Manual

Natural gas, propane, hdx35 log burner assembly
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE.
CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
NEVER LEAVE CHILDREN OR OTHER AT RISK INDIVIDUALS ALONE WITH THE APPLIANCE.
CERTIFIED TO CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA 2.22 AND ANSI Z21.50 FOR VENTED GAS FIREPLACES.
CERTIFIED FOR CANADA AND UNITED STATES USING ANSI/CSA METHODS.
SAFETY INFORMATION
WARNING
!
If the information in these instructions are
not followed exactly, a fi re or explosion
may result causing property damage,
personal injury or loss of life.
- Do not store or use gasoline or other fl ammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Immediately call your gas supplier from a
neighbour's phone. Follow the gas supplier's
instructions.
If you cannot reach your gas supplier, call the
fi re department.
- Installation and service must be performed by a
qualifi ed installer, service agency, or the supplier.
This appliance may be installed in an aftermarket,
permanently located, manufactured home (USA
only) or mobile home, where not prohibited by
local codes.
This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is
not convertible for use with other gases, unless
a certifi ed kit is used.
Decorative Product: Not for use as a heating appliance.
Phone (705)721-1212 • Fax (705)720-9081 • www.napoleonfi replaces.com • hearth@napoleonproducts.com
$10.00
INSTALLATION AND
OPERATING INSTRUCTIONS
Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada /
103 Miller Drive, Crittenden, Kentucky, USA, 41030
B35NTL
NATURAL GAS
B35PTL
PROPANE
HDX35
LOG BURNER
ASSEMBLY
DANGER
!
HOT GLASS WILL CAUSE
DO NOT TOUCH GLASS UNTIL
NEVER ALLOW CHILDREN TO
A barrier designed to reduce the risk of burns from
the hot viewing glass is provided with this appliance
and shall be installed for the protection of children
and other at-risk individuals.
AVERTISSEMENT
!
LA VITRE CHAUDE CAUSERA
NE PAS TOUCHER LA VITRE
AVANT QU'ELLE AIT REFROIDI.
ENFANTS TOUCHER LA VITRE.
BURNS.
COOLED.
TOUCH GLASS.
DES BRÛLURES.
1.22D
W415-2193 / A / 10.21.16
NE JAMAIS LAISSER LES
EN
FR
PG
15

Advertisement

Table of Contents
loading

Summary of Contents for Napoleon B35NTL

  • Page 1 AVERTISSEMENT LA VITRE CHAUDE CAUSERA Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / DES BRÛLURES. 103 Miller Drive, Crittenden, Kentucky, USA, 41030 NE PAS TOUCHER LA VITRE Phone (705)721-1212 •...
  • Page 2: Table Of Contents

    GLOWING EMBERS ADJUSTMENT FLAME CHARACTERISTICS VENTURI ADJUSTMENT REPLACEMENTS B35NTL LOG BURNER ASSEMBLY (NG) B35PTL LOG BURNER ASSEMBLY (P) NOTES NOTE: Changes, other than editorial, are denoted by a line in the margin. 1.0 GENERAL INFORMATION This burner and log assembly are approved for use in the HDX35 gas fireplace only. They are not approved for use as a stand alone appliance or in conjunction with any other appliance.
  • Page 3: Bulkheads

    BULKHEADS NOTE: Bulkhead covers need to be removed. Connect the main burner gas flex line and the pilot line to the gas fittings on the bulkheads located under the valve access opening. Care must be taken to ensure the Main pilot line isn’t damaged and ensuring gas Burner Gas tight connections are made.
  • Page 4: Hearth Panel Installation

    HEARTH PANEL INSTALLATION NOTE: It is recommended to remove the grate assembly prior to panel installation. The hearth panel is shipped separate from the appliance and is included with the mandatory brick panel kits. Due to the brittle material of the panel, care must be taken not to bend or force the panel into place. When shipped, the hearth panel range in varying shades of Sandstone / New Port.
  • Page 5: Hearth Log & Log Placement

    HEARTH LOG & LOG PLACEMENT Align the 2 holes in the bottom of the Align the 2 pins in the bottom of the top bottom rear log with the studs located rear log with the holes in the top of the on the rear log support.
  • Page 6 Align the 2 holes located in the bottom Align the 2 holes in the bottom of the of the front left crossover log with the right middle log with the 2 studs on the 2 studs on the left hand side of the right hand side of the burner.
  • Page 7: Charcoal Lumps

    CHARCOAL LUMPS WARNING CHARCOAL EMBERS, VERMICULITE AND CHARCOAL LUMPS ARE NOT TO BE PLACED ON THE BURNER. Place the lumps in front of the logs in a realistic manner taking care not to block any of the burner ports. 34.1 CHARCOAL EMBERS Randomly place the charcoal embers along the front and sides of the log support tray in a realistic manner.
  • Page 8: Adjustment

    3.0 ADJUSTMENT FLAME CHARACTERISTICS It’s important to periodically perform a visual check of the pilot and burner fl ames. Compare them to the illustration provided. If any fl ames appear abnormal call a service person. PILOT ELECTRODE BURNER 3/8” - 1/2” (9.5mm - 12.7mm) FLAME SENSOR...
  • Page 9: Replacements

    4.0 REPLACEMENTS WARNING FAILURE TO POSITION THE PARTS IN ACCORDANCE WITH THIS MANUAL OR FAILURE TO USE ONLY PARTS SPECIFICALLY APPROVED WITH THIS APPLIANCE MAY RESULT IN PROPERTY DAMAGE OR PERSONAL INJURY. Contact your dealer for questions concerning prices and policies on replacement parts. Normally, all parts ** THIS IS A FAST ACTING THERMOCOUPLE.
  • Page 10: B35Ntl Log Burner Assembly (Ng)

    W415-2193 / A / 10.21.16...
  • Page 11: B35Ptl Log Burner Assembly (P)

    W415-2193 / A / 10.21.16...
  • Page 12: Notes

    5.0 NOTES 44.1 W415-2193 / A / 10.21.16...
  • Page 13 44.1 W415-2193 / A / 10.21.16...
  • Page 14 Fireplace Inserts • Charcoal Grills • Gas Fireplaces • Waterfalls • Wood Stoves Heating & Cooling • Electric Fireplaces • Outdoor Fireplaces • Gas Grills 24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8...
  • Page 15 à risque. ÉCRAN DE PROTECTION Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON, L4M 0G8 Canada / 103 Miller Drive, Crittenden, Kentucky, USA, 41030 Téléphone 705-721-1212 • Télécopieur 705-720-9081 • www.napoleonfoyers.com • hearth@napoleonproducts.com 1.22D 10,00 $ W415-2193 / A / 10.21.16...
  • Page 16: Information Générale

    RÉGLAGES CARACTÉRISTIQUES DE LA FLAMME RÉGLAGE DU VENTURI RECHANGES BRÛLEUR DE BÛCHES DU B35NTL (GN) BRÛLEUR DE BÛCHES DU B35PTL (P) NOTES NOTE : Les modifications, autres qu’éditoriales, sont indiquées par une ligne verticale dans la marge. 1.0 INFORMATION GÉNÉRALE Ce brûleur et cet assemblage de bûches sont approuvés pour utilisation dans l’appareil au gaz HDX35...
  • Page 17: Raccords

    RACCORDS NOTE: Les couvercles des raccords doivent être retirés. Branchez les conduites de gaz flexibles et la conduite de la veilleuse aux raccords de gaz situés en dessous de l’ouverture d’accès de la soupape. Usez de prudence pour vous assurer de ne pas endommager la conduite Raccords de la veilleuse et que les connexions de gaz de gaz...
  • Page 18: Installation Des Panneaux De Plancher

    INSTALLATION DES PANNEAUX DE PLANCHER NOTE: Nous vous suggérons de enlever l’ensemble de la grillage avant l’installation du panneau. Les panneaux de plancher sont expédiés séparément de l’appareil et ils sont inclus avec l’assemblage du brûleur et les bûches. En raison de la fragilité des panneaux, prenez grand soin de ne pas courber ou forcer les panneaux pour les mettre en place.
  • Page 19: Disposition Des Bûches

    DISPOSITION DES BÛCHES Alignez les deux trous du dessous de la Alignez les deux tiges du dessous de la bûche inférieure arrière sur les goujons bûche supérieure arrière dans les trous situés sur le support à bûches arrière. sur le dessus de la bûche inférieure arrière.
  • Page 20 Alignez les deux trous du dessous de Alignez les deux trous du dessous de la bûche transversale avant gauche sur la bûche centrale droite sur les deux goujons situés à droite du brûleur. les deux goujons situés à gauche du brûleur.
  • Page 21: Morceaux De Charbon

    MORCEAUX DE CHARBON AVERTISSEMENT LES BRAISES DE CHARBON DE BOIS, LA VERMICULITE ET LES MORCEAUX DE CHARBON NE DOIVENT PAS ÊTRE PLACÉS SUR LE BRÛLEUR. Placez les morceaux de charbon devant les bûches de façon réaliste. Prenez garde de ne pas bloquer les orifi ces du brûleur.
  • Page 22: Réglages

    PILOT ELECTRODE BURNER 3/8” - 1/2” (9.5mm - 12.7mm) FLAME SENSOR 3.0 RÉGLAGES CARACTÉRISTIQUES DE LA FLAMME FLAME MUST ENVELOP UPPER 3/8” (9.5mm) TO 1/2” (12.7mm) OF FLAME SENSOR Il est important d’effectuer périodiquement une inspection visuelle de la fl amme de la veilleuse et du brûleur. Comparez-les à...
  • Page 23: Rechanges

    4.0 RECHANGES AVERTISSEMENT OMETTRE DE POSITIONNER LES PIÈCES CONFORMÉMENT À CE MANUEL OU D’UTILISER UNIQUEMENT DES PIÈCES SPÉCIFIQUEMENT APPROUVÉES POUR CET APPAREIL PEUT CAUSER DES DOMMAGES MATÉRIELS OU DES BLESSURES CORPORELLES. Contactez votre détaillant pour les questions concernant les prix et la disponibilité des pièces de ** CECI EST UN THERMOCOUPLE À...
  • Page 24: Brûleur De Bûches Du B35Ntl (Gn)

    W415-2193 / A / 10.21.16...
  • Page 25: Brûleur De Bûches Du B35Ptl (P)

    W415-2193 / A / 10.21.16...
  • Page 26: Notes

    5.0 NOTES 44.1 W415-2193 / A / 10.21.16...
  • Page 27 44.1 W415-2193 / A / 10.21.16...
  • Page 28 Poêles à bois • Produits HVAC • Foyers électriques • Foyers extérieurs • Grils à gaz de qualité 7200, Route Transcanadienne, Montréal, Québec H4T 1A3 24 Napoleon Road, Barrie, Ontario, Canada L4M 0G8 214 Bayview Drive, Barrie, Ontario, Canada L4N 4Y8...

This manual is also suitable for:

B35ptl