Test
IEC 61000-4-17
IEC 60255-5
a
Only applicable to functional earth connections separated from the safety earth connection.
IEEE 1613 EMC Immunity Type Tests
NOTE
The RUGGEDCOM RSG2300 meets Class 2 requirements for an all-fiber configuration and Class 1
requirements for copper ports.
ESD
Radiated RFI
Fast Transient
Oscillatory
HV Impulse
Dielectric Strength
Damped Oscillatory
Magnetic Field
EMC and Environmental Type Tests
Description
Ripple on DC
Power Supply
Dielectric Strength
HV Impulse
Description
Enclosure Contact
Enclosure Air
Enclosure Ports
Signal Ports
DC Power Ports
AC Power Ports
Earth Ground Ports
Signal Ports
DC Power Ports
AC Power Ports
Signal Ports
DC Power Ports
AC Power Ports
Signal Ports
DC Power Ports
AC Power Ports
Enclosure Ports
DC Power Ports
Signal Ports
2 kV (Fail-Safe
DC Power Ports
AC Power Ports
Signal Ports
5 kV (Fail-Safe
DC Power Ports
AC Power Ports
2.5 kV Common Mode @1MHz
2.5 kV common, 1 kV differential mode @ 1 MHz
2.5 kV common, 1 kV differential mode @ 1 MHz
5 kV (Fail-Safe Relay Output)
Test Levels
Severity Levels
10%
Relay Output)
2 kV
2 kV
Relay Output)
5 kV
Test Levels
+/- 2 kV, +/-4 kV, +/-8 kV
+/-4 kV, +/-8 kV, +/-15 kV
35 V/m
+/- 4 kV @ 2.5 kHz
+/- 4 kV
+/- 4 kV
+/- 4 kV
5 kV
5 kV
2 kV
2 kV
2 kV
100 A/m Peak