Départ. Technical support- CM640
PHILIPS Consumer
Communications
Centre du Mans
8.2

RF Test

8.2.1
The Test SIM Card "SP" must be inserted in t he phone before starting the tests.
8.2.2
Set the equipment as shown on the picture in chapter 6.2
8.2.3
Set RF losses as following (tested with antenna coupler):
Channel
900 MHz
8.2.4
The following operations must be done:
8.2.5
The following parameters must be checked in TCH loop mode :
Emission parameters :
Reception parameters :
Generally the test sequences built inside the testers will be used to check the mobile. You must assess that the test
sequences limits comply with the standard specifications and defined test plan.
© PHILIPS ELECTRONICS N.V. 1999
All rights reserved. Reproduction in whole
or in part is prohibited without the written
consent of the copyright owner.
PROCEDURE
RX
TX
63
5,0
5,2
3
4,0
3,2
62
5,0
5,2
123
6,0
4,1
-
Synchronization/Registration
-
Call set up from the mobile
-
Voice loopback ( to check the sound quality)
-
Call release
-
Call set up from tester
-
Call release from tester
-
Power level
-
RMS phase error
-
Peak phase error
-
Frequency error
-
Power ramping
Timing Advance
-
-
Rx level
-
Rx quality
-
BER (Byte Error Rate)
-
FER (Frame Error Rate)
Service Repair Support
1800 MHz
COMPANY RESTRICTED
VY-V-640-204
Page : 16 of 42
Langue : EN
Date : 09/21/01
Channel
RX
598
27,0
512
23,0
700
27,0
884
19,0
VY-V-640-204
TX
13,0
10,0
13,0
16,7