Troubleshooting - Danby DAC080ECB3GDB Owner's Use And Care Manual

Table of Contents

Advertisement

Available languages

Available languages

TROUBLESHOOTING

Occasionally a problem may arise that is minor in nature, and a service call may not be neccessary. Use this troubleshoot-
ing guide for a possible solution. If the unit continues to operate improperly, call an authorized service depot or
Danby's Toll Free Number 1-800-263-2629 for assistance.
PROBLEM
Air conditioner will
not operate
Ineffi cient or no cool-
ing
Noisy unit
Odors
Water dripping
outside
Water dripping inside •
Ice or frost build-up
NOTES:
1. If circuit breaker is tripped repeatedly, or fuse is blown more than once, contact a qualifi ed technician.
2. When the unit is installed using proper installation steps, the unit is properly tipped toward the outdoors to allow for
condensation run-off.
POSSIBLE CAUSE
No power to the unit
Dirty air fi lter
Unit size inappropriate for application •
Blocked air fl ow
Power interruption, settings changed
too quickly, or compressor overload
tripped
Loose parts
Inadequate support
Formation of mold, mildew, or algae
on wet surfaces
Hot and humid weather
Unit is not properly angled to allow
water to drain outside
It is an extremely humid day
Low outside temperature
Unit air fi lter is dirty
SOLUTION
Check connection of power cord to power
source.
Check fuse or circuit breaker.
Set SELECTOR SWITCH to position other than
"OFF". The power cord "RESET" button must
always be pushed in (engaged) for correct op-
eration.
Clean/replace air fi lter
Check with dealer to determine proper unit ca-
pacity for application
Remove obstruction from grill or outdoor louvres
Turn the unit off and wait 5 minutes before at-
tempting to restart
Tighten loose parts
Provide additional support to unit
Clean unit thoroughly
Place algaecide tablet in base pan
Condensation run-off is normal under these
conditions.
Unit must be installed on an angle for proper
condensation run-off. Check the unit and make
any adjustments.
On an extremely humid day, this effect is expect-
ed. No action required.
When outdoor temperature is approximately
18.3°C (65°F) or below, frost may form when
unit is in cooling mode. Switch unit to FAN (only)
operation until frost melts.
Remove and clean fi lter
12

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dac080eub3gdbDac120ecb3gdbDac120eub3gdb

Table of Contents