Trane 4TWR3 Installer's Manual
Hide thumbs Also See for 4TWR3:

Advertisement

Quick Links

ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES
IMPORTANT — This Document is customer property and is to remain with this unit. Please return to service information
pack upon completion of work.
These instructions do not cover all variations in
systems nor provide for every possible contingency
to be met in connection with installation. All phases
of this installation must comply with NATIONAL,
STATE AND LOCAL CODES. Should further informa-
tion be desired or should particular problems arise which
are not covered sufficiently for the purchaser's purposes,
the matter should be referred to your installing dealer or
local distributor.
A. GENERAL
WARNING
!
This information is intended for use by individuals posses-
sing adequate backgrounds of electrical and mechanical
experience. Any attempt to repair a central air conditioning
product may result in personal injury and or property
damage. The manufacturer or seller cannot be responsible
for the interpretation of this information, nor can it assume
any liability in connection with its use.
NOTICE:
Trane has always recommended installing Trane approved
matched indoor and outdoor systems.
The benefits of installing approved matched systems are
maximum efficiency, optimum performance and best
overall system reliability.
WARNING
!
These units use R-410A refrigerant which operates at 50 to
70% higher pressures than R-22. Use only R-410A approved
service equipment. Refrigerant cylinders are painted a
"Rose" color to indicate the type of refrigerant and may
contain a "dip" tube to allow for charging of liquid refriger-
ant into the system. All R-410A systems use a POE oil that
readily absorbs moisture from the atmosphere. To limit this
"hygroscopic" action, the system should remain sealed
whenever possible. If a system has been open to the
atmosphere for more than 4 hours, the compressor oil
must be replaced. Never break a vacuum with air and always
change the driers when opening the system for component
replacement. For specific handling concerns with R-410A
and POE oil, reference Retrofit Bulletin TRN-APG02-EN.
Check for transportation damage after unit is uncrated.
Report promptly, to the carrier, any damage found to the unit.
To determine the electrical power requirements of the unit,
refer to the nameplate of the unit. The electrical power
available must agree with that listed on the nameplate.
Installer's Guide
Heat Pumps
4TWR3 & 4TWR4
UNIT CONTAINS R-410A REFRIGERANT!
R-410A OPERATING PRESSURE EXCEEDS THE
LIMIT OF R-22. PROPER SERVICE EQUIPMENT IS
REQUIRED. FAILURE TO USE PROPER SERVICE
TOOLS MAY RESULT IN EQUIPMENT DAMAGE OR
PERSONAL INJURY.
1
The Weathertron
factured to withstand and operate in severe winter condi-
tions. However, there are precautionary steps which should
be taken at the time of installation which will help assure
the efficient operation of the unit. It is recommended that
these precautions be taken for units being installed in
areas where snow accumulation and prolonged below
freezing temperatures occur.
1. Units should be elevated 3 to 12 inches above the pad or
rooftop, depending on local weather. This additional
height will allow better drainage of snow and ice (melted
during defrost cycle) prior to its refreezing. This should
prevent a build-up of ice around the unit which occurs
when unit is not elevated. Insure that drain holes in
unit base pan are not obstructed preventing
draining of defrost water.
2. If possible, avoid locations that are likely to accumulate
snow drifts. If not possible, a snow drift barrier should be
installed around the unit to prevent a build-up of snow on
CAUTION
!
SERVICE
USE ONLY R-410A REFRIGERANT AND
APPROVED POE COMPRESSOR OIL.
5 FT. ABOVE UNIT — UNRESTRICTED
®
Heat Pump has been designed and manu-
18-BC51D1-4

Advertisement

Table of Contents
loading

Summary of Contents for Trane 4TWR3

  • Page 1 NOTICE: Trane has always recommended installing Trane approved matched indoor and outdoor systems. The benefits of installing approved matched systems are maximum efficiency, optimum performance and best overall system reliability.
  • Page 2 6. Uncoil the tubing — do not kink or dent. is not the application used please refer to application 7. Route the tubing making all required bends and properly bulletin “Trane XR-APG**-EN” (* denotes latest secure the tubing before making connections. revision number).
  • Page 3 Installer’s Guide NOTICE: GAS LINE BALL SERVICE VALVE Precautions should be taken to avoid heat damage to basepan during brazing. It is recommended to keep the 1/4 TURN ONLY flame directly off of the basepan. COUNTERCLOCKWISE FOR FULL OPEN POSITION 7.
  • Page 4: Electrical Connections

    Installer’s Guide 10. The gas valve can now be opened. For a ball type gas In normal operation, the defrost control light will flash once valve, open the gas valve by removing the shut-off valve each second. If the light is flashing more than once per cap and turning the valve stem 1/4 turn counterclock- second or not at all, refer to the service manual for that unit.
  • Page 5: Troubleshooting

    Installer’s Guide I. ELECTRIC HEATERS M. TROUBLESHOOTING Electric heaters, if used, are to be installed in the air han- TROUBLESHOOTING CHART — WHAT TO CHECK dling device according to the instructions accompanying the air handler and the heaters. SYSTEM FAULTS J.
  • Page 6: Subcooling Charging In Cooling Above 55°F Od Ambient

    Trane approved matched indoor and outdoor systems. twenty (20) minutes for the system conditions to stabilize before adjusting charge again. All Trane split systems are ARI rated with only TXV indoor systems. 8. When system is correctly charged, you can refer to...
  • Page 7 Installer’s Guide 4TWR3 & 4TWR4 OUTLINE DRAWING NOTE: ALL DIMENSIONS ARE IN MM (INCHES). MODELS BASE FIG. 4TWR3018A 730 (28-3/4) 829 (32-5/8) 756 (29-3/4) 127 (5) 76 (3) 197 (7-3/4) 57 (2-1/4) 508 (20) 4TWR3024A 730 (28-3/4) 829 (32-5/8) 756 (29-3/4)
  • Page 8: Mounting Hole Location

    7. Indoor coil drain line drains freely. Pour water into drain pan ............... [ ] Trane A business of Trane has a policy of continuous product and product data improvement and it reserves the right to change American Standard Companies www.trane.com design and specifications without notice.

This manual is also suitable for:

4twr4

Table of Contents