Refrigerant Cycle Diagram - Toshiba RAS-07EKV-EE Service Manual

Indoor unit outdoor unit
Table of Contents

Advertisement

7-1. Refrigerant Cycle Diagram

RAS-07EKV-EE / RAS-07EAV-EE
RAS-10EKV-EE / RAS-10EAV-EE
P
Pressure measurement
Gauge attaching port
Vacuum pump connecting port
Deoxidized copper pipe
Outer dia. : 9.52mm
Thickness : 0.8mm
4-way valve
TS
Temp. measurement
7. REFRIGERANT CYCLE DIAGRAM
INDOOR UNIT
Indoor heat
exchanger
Cross flow fan
Deoxidized copper pipe
Outer dia. : 6.35mm
Thickness : 0.8mm
Sectional shape
of heat insulator
Muffler
Muffler
TD
Compressor
DA89X1C-23EZ
Outdoor heat
exchanger
T2
Propeller fan
OUTDOOR UNIT
T1
Temp. measurement
TC
TA
TO
Split capillary
Ø1.2 x 100
Ø1.2 x 100
TE
NOTE :
– 19 –
FILE NO. SVM-13029
Max.
Min.
Chargeless : 10m
Strainer
Pulse Modulating
valve at liquid side
Strainer
Refrigerant amount : 0.63kg
Gas leak check position
Refrigerant flow (Cooling)
Refrigerant flow (Heating)
: 10m
: 2m