15. Disassembly and Assembly Instructions
High Voltage is generated in the electrical parts area by the capacitor. Ensure that the capacitor has discharged sufficiently before proceeding with
repair work. Failure to heed this caution may result in electric shocks.
15.1 CS-PS36RKV
15.1.1 Indoor Electronic Controllers, Cross Flow Fan and Indoor Fan Motor Removal
Procedures
15.1.1.1
To remove front grille
2.Remove 3 caps and 3 screws at the bottom of discharge vane
15.1.2 To remove electronic controller
WARNING
Figure 1
Figure 1
Figure 2
62
87
3.Hold both sides of the front grille and
remove it by pulling up and toward
yourself gently
1.Lift to open the horizontal vane gently
4.Remove screw
and pull out the
control board cover.
Hooks (right hand side)