Installation
1. Connect the component A supply to the A side
fitting (19a) of the mix manifold.
2. Connect the component B supply to the B side
fitting (19b) of the mix manifold.
3. Connect the solvent supply to the solvent fitting
(20) of the mix manifold.
4. Connect the static mixer hose (106) to the gun
whip hose.
This equipment must be grounded to reduce
the risk of static sparking. Static sparking can
cause fumes to ignite or explode. Grounding
provides an escape wire for the electric current.
5. Connect the ground wire (105) to the ground
screw (23). Connect the other end of the ground
wire to a true earth ground.
Figure 1 Mix Manifold
3A2801A
Operation
1. Check that all hose connections are tight before
each use.
2. To spray, move the lever (16) to the
(SPRAY) position. Components A and B will
enter the mix manifold and be mixed by the mix
nozzle (10) and the static mixer tube (106).
3. To flush, move the lever (16) to the
position. Solvent will flush the mix manifold,
static mixer, and gun.
4. To shut down, flush the mix manifold and relieve
pressure as described in the PD2K operation
manual. Always leave the mix manifold lever in
the
(FLUSH) position when not in use.
Figure 2 Mix Manifold Set to Spray
Figure 3 Mix Manifold Set to Flush
Installation
(FLUSH)
5