Set Temperature Rise

CAUTION
!
UNIT DAMAGE HAZARD
Failure to follow this caution may result in component
damage.
Temperature rise must be within limits specified on unit
rating plate. Operation is within a few degrees of midpoint
of rise range when setup switch SW1- -4 is OFF.
Furnace must operate within ranges of temperature rise specified
on the furnace rating plate. Determine air temperature rise as
follows:
1. Place thermometers in return and supply ducts as near fur-
nace as possible. Be sure thermometers do not see heat ex-
changer so that radiant heat does not affect readings. This
practice is particularly important with straight- -run ducts.
2. When thermometer readings stabilize, subtract return- -air
temperature from supply- -air temperature to determine air
temperature rise.
NOTE:
Temperature rise can be determined for low- -heat
operation by placing setup switch SW1- -2 on furnace control in
Table 12 – Gas Rate cu Ft/Hr
SIZE OF TEST DIAL
1
2
5
REVOLUTION
cu ft.
cu ft.
cu ft.
360
720
1800
327
655
1636
300
600
1500
277
555
1385
257
514
1286
240
480
1200
225
450
1125
212
424
1059
200
400
1000
189
379
947
180
360
900
171
343
857
164
327
818
157
313
783
150
300
750
144
288
720
138
277
692
133
267
667
129
257
643
124
248
621
120
240
600
116
232
581
113
225
563
109
218
545
106
212
529
103
206
514
100
200
500
97
195
486
95
189
474
92
185
462
90
180
450
88
176
439
86
172
429
84
167
419
82
164
409
80
160
400
78
157
391
76
153
383
75
150
375
73
147
367
SIZE OF TEST DIAL
SECONDS
FOR 1
1
2
cu ft.
cu ft.
50
72
144
51
71
141
52
69
138
53
68
136
54
67
133
55
65
131
56
64
129
57
63
126
58
62
124
59
61
122
60
60
120
62
58
116
64
56
112
66
54
109
68
53
106
70
51
103
72
50
100
74
48
97
76
47
95
78
46
92
80
45
90
82
44
88
84
43
86
86
42
84
88
41
82
90
40
80
92
39
78
94
38
76
96
38
75
98
37
74
100
36
72
102
35
71
104
35
69
106
34
68
108
33
67
110
33
65
112
32
64
116
31
62
120
30
60
ON position. Temperature rise can be determined for
medium- -heat operation by placing setup switch SW4- -2 on
furnace control in ON position. For high- -heat operation, place
setup switch SW1- -2 and SW4- -2 in OFF position and jumper
R- -W2 on furnace control. DO NOT forget to return setup switch
to OFF position and remove R- -W2 jumper upon completion of
testing. (See Fig. 33 for switch and terminal location.)
3. This furnace is capable of automatically providing proper
airflow to maintain the temperature rise within the range
specified on furnace rating plate. If temperature rise is out-
side this range, proceed as follows:
a. Check gas input for low- -, medium- -, and high- -heat oper-
ation.
b. Check derate for altitude if applicable.
c. Check all return and supply ducts for excessive restric-
tions causing static pressure greater than 0.5- -in. wc.
d. Ensure Low Heat Rise Adjust switch SW1- -3 on furnace
control is in ON position when a bypass humidifier is
used. (See Fig. 33 for switch location.)
e. Check Troubleshooting Guide for Variable- -Speed Step
Modulating Condensing Furnaces.

Set Thermostat Heat Anticipator

When using a non- -electronic thermostat, the thermostat heat
anticipator must be set to match the amp draw of components in
59
5
cu ft.
360
355
346
340
333
327
321
316
310
305
300
290
281
273
265
257
250
243
237
231
225
220
214
209
205
200
196
192
188
184
180
178
173
170
167
164
161
155
150

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Plus 95sPlus 95s 355cavPlus 95s355cav

Table of Contents