Nabco GT 1505 Installation Manual

Bump out convenience window

Advertisement

Quick Links

Associated Manuals Part Numbers: U30 Microprocessor Control Setup and Programming Manual P/N C-00203
• Turn OFF all power to the Automatic Convenience Window if a Safety System isn't working.
WARNING
• Instruct the Owner to keep all power turned OFF until corrective action can be achieved
• NEVER leave a Window operating without all Safety detection systems operational.

Table of Contents

CHAPTER 1: WARNING LABELS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
CHAPTER 2: GENERAL SAFETY RECOMMENDATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
CHAPTER 3: SCOPE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
SECTION 3.1: To the Installer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
SECTION 3.2: Objective . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
CHAPTER 4: GETTING STARTED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
SECTION 4.1: Common Service Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
SECTION 4.2: Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
CHAPTER 5: INSTALL THE BUMPOUT WINDOW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
SECTION 5.1: Inspect the Rough Opening . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
SECTION 5.2: Secure Window Frame to Building . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
CHAPTER 6: GENERAL WIRING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
SECTION 6.1: General Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
SECTION 6.2: Wire Unit to Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
CHAPTER 7: ADJUST THE DRIVE BELT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
CHAPTER 8: HANDY TERMINAL PROGRAMMING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
**with U30 Microprocessor Control; Revision "E" Software**
Nabco Entrances Inc. S82 W18717 Gemini Drive Muskego, Wisconsin 53150
Phone: (877) 622-2694 Fax: (888) 679-3319 www.nabcoentrances.com
NABCO hours of Operation: Monday to Friday 8:00 a.m.- 4:30 p.m. (Central Time)
by a NABCO trained technician. Failure to follow these practices may result in serious
consequences.
GT 1505 Bump Out Convenience Window
Installation Manual
P/N C-00208 Rev 12-15-17
1 of 8

Advertisement

Table of Contents
loading

Summary of Contents for Nabco GT 1505

  • Page 1: Table Of Contents

    WARNING • Instruct the Owner to keep all power turned OFF until corrective action can be achieved by a NABCO trained technician. Failure to follow these practices may result in serious consequences. • NEVER leave a Window operating without all Safety detection systems operational.
  • Page 2: Chapter 1: Warning Labels

    . Any sharp objects that come in contact with glass may cause the glass to shatter . NABCO Entrances is not responsible for glass that is broken during the installation of this Unit .
  • Page 3: Chapter 3: Scope

    If after troubleshooting a problem, a satisfactory solution cannot be achieved, please call Nabco Entrances at 1-877-622-2694 between 8 am – 4:30 pm Central time for additional assistance. All installation changes and adjustments must be made by qualified, NABCO trained technicians.
  • Page 4: Section 5.2: Secure Window Frame To Building

    Rough Opening through the Header and at the Bottom . Notice: The GT-1505 Convenience Window is assembled at the NABCO Entrances Factory. No disassembly is required. If any part of the GT-1505 Bump Out Convenience Window is disassembled during installation, it will be the responsibility of the Installer to return the Unit back to its original factory condition.
  • Page 5 Use an appropriate tap drill to drill a pilot hole. 6. Secure Jamb Tubes with 1/4 inch diameter screws. a. Fasteners are not provided by NABCO. b. Ensure each visible screw head is flush on face of Jamb Tube. c. Do not overtighten fasteners to prevent deforming the Jamb Tube.
  • Page 6: Chapter 6: General Wiring

    WARNING and Local electrical codes/regulations . Attention:  Electrical circuit to Nabco operator must not be not shared with other equipment such as lighting, cash registers, or any device that might cause electrical interference on the circuit . SECTION 6 .1: General Wiring Diagram...
  • Page 7: Chapter 7: Adjust The Drive Belt

    1. Upon initializing the Handy Terminal, press the ENTRY button until the desired Adjustment Function is displayed. 2. Start the programming  Press the Shift buttons to select Y Press ENTRY Unique Values for Bumpout Window and NABCO Default Quick Reference Table Standard Function...
  • Page 8 GT1505 Bump Out Convenience Window Installation Manual www.NabcoEntrances.com P/N C-00208 Rev 12-15-17 Unique Values for Bumpout Window and NABCO Default Quick Reference Table Extra Function Function (1) Adjustment Value Description Unique to Bumpout NABCO Default Adjustments Function (2) Function (3)

Table of Contents