Quinton TM55 Service Manual page 43

Cardiac stress treadmills
Hide thumbs Also See for TM55:
Table of Contents

Advertisement

Cardiac Stress Treadmills Service Manual
2. Restore power to the treadmill, then use the grade motor to turn the
pinion shaft until the setscrew on the sprocket is visible.
Chain
Grade Motor
3. Turn off the power and the treadmill circuit breaker, then unplug the
treadmill.
4. Loosen the setscrews from the grade sprocket.
5. Remove the grade motor chain as described on page 4-13.
6. Remove the handrail support bracket on the right side.
7. Slide out the pinion shaft.
8. Slide the new pinion shaft into place: be sure to reinstall the grade
sprocket and key while installing the pinion shaft.
9. Replace the handrail support bracket.
10. Use a straight edge to align the grade sprocket and grade motor
sprocket, then tighten the setscrew.
11. Replace the grade motor chain as previously described.
12. Reassemble the deck assembly and poly-V drive belt.
13. Reassemble the rack gear.
14. Calibrate the grade potentiometer (see "Calibration Procedures" on
page 4-26).
15. Test the treadmill grade. Verify that:
a. it operates over the full range of 0-25%.
b. there is no binding when it moves up or down.
c. the grade motor chain is aligned correctly. A popping sound in the
chain indicates misalignment.
16. Unplug the treadmill. If no other service is required, replace the
treadmill hood as described in step 9 on page 4-3.
17. Replace the side bumpers.
Pinion Shaft
Repair/Replacement and Calibration 4-19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tm65St55St65

Table of Contents