  • Page 1 Compressor Nebulizer C102 Total (NE-C102-E) X102 Total (NE-C102-EO) Instruction Manual IM-NE-C102-E-04-11/2020 3A4477 rev.00 Issue Date / Date de publication / Ausgabedatum / Data di pubblicazione / Fecha de publicación / Uitgiftedatum / : 2020-12-09 / Data publikacji / Utgivningsdatum /...
  • Page 2: Table Of Contents

    Table of Contents Intended use ................3 Know your unit .................4 How the nebulizer kit works .............5 How the Nasal Shower works ..........6 Important safety instructions (Read before use) ......7 How to use ................8 Cleaning and daily disinfecting ..........10 ..............12 ................13 Warranty .................16 Optional Medical Accessories ..........17 Other Optional/Replacement Parts ........17...
  • Page 3: Intended Use

    Intended use Medical Purpose rinsing the nasal and rhino-pharyngeal cavities. Intended User • Legally certified medical experts, such as doctor, nurse and therapist. • Caregiver or patient under the guidance of qualified medical experts for home treatment. • Intended Patients Persons who suffer from respiratory disorders and require inhalation of medications or who require rinsing of their nasal and rhino-pharyngeal cavities.
  • Page 4: Know Your Unit

    Know your unit Compressor (Main unit) Rear View Power Switch Power Cord Connector Air Filter Cover Including air filter Nebulizer Kit Holder Power Plug Ventilation Slots Ventilation Slots Power Cord Compartment Nebulizer Kit (PVC, 100 cm) Vaporiser Head Nozzle Adapter Mouthpiece Adult Mask (PVC) Child Mask (PVC)
  • Page 5: How The Nebulizer Kit Works

    Nasal Shower Nasal adapter Upper part Nozzle O-ring (Max 15 ml) Button Lower part How the nebulizer kit works Baffle the medication channel is mixed with Aerosol Aerosol compressed air which is generated by a compressor pump. Nozzle Medication Medication is turned into fine particles and sprayed when in contact with the baffle.
  • Page 6: How The Nasal Shower Works

    How the Nasal Shower works Aerosol Aerosol the channel is mixed with compressed air which is generated by a compressor pump. turned into fine particles ready for irrigation for the nasal and rhino-pharyngeal cavities. Solution Solution Compressed Air...
  • Page 7: Important Safety Instructions (Read Before Use)

    Important safety instructions (Read before use) Warning 1. Use the device only as nebulizer for therapeutic purposes. Any other liable for improper uses. 2. Do not use in anaesthetic or ventilator breathing circuits. 3. Always disconnect the power plug after use. could get hot and there is a possible risk of a burn if touched.
  • Page 8: How To Use

    How to use 1. Make sure that the power switch is in the off ( position. 2. Plug the power plug into a power outlet. Note: Do not place the device in a location where it is difficult to disconnect the power cord. 3.
  • Page 9 nebulization begins and aerosol is generated. Gently inhale the medication. Exhale through the nebulizer kit. 11. When treatment is completed, turn the power off and unplug the compressor from the power outlet. Wind the power cord up and store it in the compartment at the back of the device. Preparation of the Nasal Shower 1.
  • Page 10: Cleaning And Daily Disinfecting

    Cleaning and daily disinfecting Carefully wash your hands before cleaning and disinfecting the nebulizer will prevent inefficient nebulization and reduce risk of infection. Adapter: Fully disassemble the Nebulizer Kit and the Nasal Shower. Wash them in warm water and mild, neutral detergent. Rinse them thoroughly with clean hot tap water, gently tap to remove excess water and allow to air dry in a clean place.
  • Page 11 Replacing the Air Filter: If the air filter has changed color, or has been used for more than 70 applications, replace it with a new Replacement Parts” paragraph. Remove the air filter cover using a flat screwdriver as shown in figure; remove the filter and fit the new filter as shown.
  • Page 12 Do not attempt to repair the device. Do not open and/or tamper with the device. No parts of the device are user serviceable. Return the device to an authorized OMRON retail outlet or distributor. Please report to the manufacturer and the competent authority of the Member State in which you are established about any serious incident that has occurred in relation to this device.
  • Page 13 Technical data Product Category: Aerosoltherapy Equipment Product Description: Compressor Nebulizer Model (code): Rating: Power Consumption: 150VA Operating Mode: Continuous Use +5°C to +40°C / Humidity/Air Pressure: 15% to 85%RH / 700 to 1060 hPa -20°C to +60°C / 5% to 95%RH / Air Pressure: 500 to 1060 hPa Weight:...
  • Page 14 General Notes: • IP classification is degrees of protection provided by enclosures in accordance 12 mm diameter and greater such as a finger, and against vertically falling water drops which may cause issues during a normal operation. • Subject to technical modification without prior notice. •...
  • Page 15 Nebulizer Kit: Result of cascade impactor measurements for particle Cumulative % particle mass of sodium fluoride undersize Mean Individual Notes: • Performance may vary with drugs such as suspensions or high viscosity. See drug supplier’s data sheet for further details of medication.
  • Page 16: Warranty

    It is designed to give you every satisfaction, provided that it is properly operated and maintained as described in the instruction manual. of this product is guaranteed by OMRON. During this period of guarantee OMRON will, without charge for labour or parts, repair or replace the defect product or any defective parts.
  • Page 17: Optional Medical Accessories

    (EMC) to EN60601-1-2:2015 Electro Magnetic Compatibility (EMC) standard. Further documentation in accordance with this EMC standard mentioned in this instruction manual or at www.omron-healthcare.com. Refer to the EMC information for NE-C102-E/-EO on the website. DISPOSAL PROCEDURE (Dir. 2012/19/EU-WEEE) must be returned to a collection point for recycling electric and electronic devices.
  • Page 18 3A HEALTH CARE S.r.l. Via Marziale Cerutti, 90F/G 25017 Lonato del Garda (BS) Italy Distributor www.omron-healthcare.com Subsidiaries Importer in OMRON HEALTHCARE UK LTD. the United Opal Drive, Fox Milne, Milton Keynes, Kingdom and MK15 0DG, UK UK responsible www.omron-healthcare.com person...