QuickStart
MODELS MADCBB, MATDCBB, MASDCBB, & MASTDCB
This Quick Start is intended to highlight the features and functions of the Mega Arm Gate Operator. Refer to the
installation manual for complete information regarding installation and programming.
INTRODUCTION
The operator functions can be customized by changing various DIP switches, and wiring auxiliary devices to the
control board on the J5 terminal strip.
DEFAULT SETTINGS ARE AS FOLLOWS:
• Timer-to-Close is activated and set to four seconds.
• Radio receiver is wired to open only.
• The barrier arm is set to right-hand gate operation.
NOTE: Right-hand or left-hand operation is determined by facing the control board with the barrier
arm in the CLOSED position. If the barrier arm is to the right, it is set for right-hand gate operation.
• Motor speed is set to approximately 2.5 seconds of fast run time.
• Fail Safe is set for Auto Open after batteries drop below 50%.
OVERVIEW
A
The S1 and S2 DIP switches work together with devices wired into the J5 terminal strip. The DIP switch
settings can be set to control various features such as K1 Relay (optional), Timer-to-Close, Single Button
Function, and Fail Safe (Auto Open on AC Power Failure).
B
The S3 DIP switch is a service switch used to open and close the barrier arm from the control board.
NOTE: The S3 DIP switch should be set to CLOSE for normal operation.
C
The J5 terminal strip is used for controlling the barrier arm with various accessories such as Receivers,
Loop Detectors, Access Controls, and Push Button Stations.
D
The J4 Motor Wiring is controlled by DIP switch S1-7. The gate operator default setting
for DIP switch S1-7 is in the OFF position, and set for right-hand gate operation.
E
The K1 Relay (optional) and terminal strip (J1) are used for auxiliary devices such as Counters, Alarms,
Buzzers, and SAMS (Sequence Access Management System).
programming guide for MEGA Arm Gate Operators
A
DIP Switches
ON
S1
S2
1
2
3
4
5
6
7
8
OFF
F
Limit Cam Position
CAM POSITION
E
K1 Relay (optional) and Terminal Strip (J1)
K1
AUX RELAY
J1
C
NC
NO
DC
PWR
B
Manual Switch
MANUAL
OPEN
S3
ON
CLOSE
1
2
3
4
5
6
7
8
OFF
J5
C
J5 Terminal Strip (Wiring Inputs)
1
2
3
4
5
6
J5
D
J4 Motor Wiring
(Factory default right-hand gate operation shown below.)
MOTOR
J4
ACC+ ACC– BAT–
BAT+
24VAC XFMR
MOTOR
7
8
9

Advertisement

loading

Summary of Contents for Chamberlain MADCBB

  • Page 1 QuickStart programming guide for MEGA Arm Gate Operators MODELS MADCBB, MATDCBB, MASDCBB, & MASTDCB This Quick Start is intended to highlight the features and functions of the Mega Arm Gate Operator. Refer to the installation manual for complete information regarding installation and programming.