Dometic 5 Series Installation Manual page 26

Absorber refrigerator
Hide thumbs Also See for 5 Series:
Table of Contents

Advertisement

Available languages

Available languages

Connecting the refrigerator
9.2
Connecting to 12 Vg and 230 Vw
A
NOTICE!
• The electrical installation and repairs may only be performed by a
specialist in accordance with the applicable regulations and
standards.
• According to EN 1648-1, the respective negative and positive cables
of the DC connections for heating and lighting may not be joined
with one another in a caravan. This can cause electrical interference
or damage to electrical components.
• The inverter may only be connected by a specialist.
I
NOTE
• The mains socket must be easily accessible so that you can unplug
the power cord if required, thereby disconnecting the refrigerator
from the power.
• The plug of the AC connection cable must not be cut off.
• The connection cables must be laid so that they do not come in con-
tact with hot parts of the unit/burner or with sharp edges.
• Changes to the internal electrical installation or the connection of
other electrical components (e.g. extra third party fans) to the inter-
nal wiring of the refrigerator will void the E1/CE approval and any
claims from the guarantee and product liability.
➤ Connect the RM5310/RM5330/RM5380 refrigerators according to fig. e,
page 12 (without lighting), and fig. f, page 13 (with lighting):
Item
Description
1
Heating element DC
2
DC connection cable
3
Terminal strip for the DC power supply of the heating cartridge
4
Positive cable of the heating cartridge
5
Earth cable of the heating cartridge
6
Positive cable of the lighting
7
Reed contact switch (sensor switch)
8
Galvanometer
9
LED lighting
10
Thermal power adapter
26
RM5310, RM5330, RM5380
EN

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rm 5310Rm 5330Rm 5380

Table of Contents