Hot water set-up

To set-
activation of the hot water mode is required. Hot water temperatures can not be changed dependent on the outdoor
conditions, they will remain constant. The factory settings for the flow temperature is 50°C but this should be increased to
55°C.
1
2
3
4
Limit Temp
Function
5
Select
Hot Water
H
6
H
On
PAR-W21MAA
Hot Water mode
Throughout the system set-up buttons on the controller are referenced by letters and displays by numbers ; this key can be found on page 41
44
SYSTEM SET -UP
Normal Display
D E
Change Language
E
Function Selection
G
G
Locking
Function
D
D
Select
Select
Anti Freeze
Cooling
Off
H
Factory Settings
Recommended Settings
50°C
55°C
G
Select
Mode
D
G
D
D
Select
Heating
Step 6:
H will alternate between on and off. Pressing D will
go through the process on step 5.
Table 2.9
43
Step 1:
Hold down buttons D and E for 2 seconds.
This activates the controller
Step 2:
Press button E. The language is preset to English.
See full manual if you wish to change this setting.
Step 3:
Press button G to advance
Step 4:
At this stage a choice of 3 screens will
appear, each press of button G will
change the function. You will need to
button D to move forward
Step 5:
At this stage a choice of 5
screens will appear, each
Select
press of button D will
Eco Heating
change the function. You
D
Finish:
Press button A. Hold down
buttons D and E for 2
seconds to return to
original screen.