ADTRAN Total Access OPTI-3 CPE OPTI-3 CPE Product Manual

Controller module

Advertisement

Quick Links

OPTI-3
CONTROLLER
The Total Access
®
OPTI-3 Controller Module (OCM) provides an OC-3 interface to the network and three ADD/DROP DS3
interfaces to the Loop. The OCM can be configured for a point-to-point configuration or subtended from 3rd party SONET
equipment. The OCM operates in terminal mode only. The compact design mounts in either a rackmount or wallmount
chassis, requiring less space and provides optional redundancy. It can automatically switch to the offline unit in the event of
optical signal failure or degradation. The modules are fully hot-swappable.
Compliant with SONET standards, the OCM functions as a terminal multiplexer. It supports 1+1 OC-3 equipment and facility
protection, 1:1 OC-3 equipment protection (system provisioned for optical Ycable), 1:1 DS3 facility protection, and detects
standard optical related alarm conditions. The OCM can be configured to operate redundantly with optional protection of
the optics components. It can be upgraded online from un-protected to protected and operating software can be upgraded
remotely in Back-to-Back configurations.
The OCM is easily managed with TL1 commands over the Data Communications Channel (DCC) or via Command Line
Interface (CLI) through the local craft interface. Additional features include remote alarm transport via DCC and alarm
reporting to legacy alarm systems.
This job aid relates to OPTI-3 System Release 1.3 (Dseries). The menus and functionality are an extension of the prior system
release (OPTI-3 System Release 1.2 - Cseries). The latest software is not compatible with System Release 1.1 (Bseries).
1
The Total Access OPTI-3 can be installed in either a Rackmount Chassis (RMC), P/N 1184003L1, or a Wallmount Chassis
(WMC), P/N 1184001L1. The RMC provides two OCM slots, side by side, with slot A on the left and slot B on the right. (See
Figure below.) The WMC provides two OCM slots, positioned vertically with slot A below slot B. Ensure the appropriate
chassis is installed before proceeding with the OCM installation.
Carefully insert the OCM halfway into the selected slot. Route the fiber cables through the notch on the OCM front panel and
approximately 4 inches past the SC receptacles (to create slack). Gently but firmly push the OCM all the way into the slot,
being careful not to pinch the fibers between the front panel and the shelf. Push the latch/ejector tab toward the front panel
to lock it into place.
WARNING: Once fully inserted into the chassis, the module will be powered (provided power is connected to the chassis).
2
When the OCM powers up, it performs a self-test. The front panel LEDs illuminate for approximately 8 seconds. The self-test
is complete once the STATUS LED illuminates green.
3
If installing a redundant system, repeat the preceding procedure for slot B. If not installing a second OCM, a blank faceplate
(P/N 1184005L1) must cover the empty slot.
C A U T I O N !
C A U T I O N
SUBJECT TO ELECTROSTATIC DAMAGE
OR DECREASE IN RELIABILITY.
HANDLING PRECAUTIONS REQUIRED.
TOTAL ACCESS OPTI-3 CONTROLLER MODULE
APS
TEST
ACO
CRAFT
ENABLE
#61184002L4-22B#
1550 NM
OPTI-3
1184002L4
Green
1550nm
Yellow
Flashing Yellow Unit is Out-of-Service – Maintenance or is ONLINE and inhibited
Red
Green
Yellow
Flashing Yellow Unit in Test (e.g. Loopback)
Red
Flashing Red
Green
Yellow
Flashing Yellow Unit in Test (e.g. Loopback)
Red
Flashing Red
Yellow
Flashing Yellow When displayed on the OCM at the CO, indicates an unacknowl-
Red
Flashing Red
When depressed simultaneously with the TEST/ENABLE switch on the Offline unit, a switch is forced
between the two OCMs.
When depressed with the TEST/ENABLE switch on the Online unit, it toggles LOCKOUT status.
When depressed alone, tests all unit LEDs (multicolor LEDs appear YELLOW).
When depressed simultaneously with the APS switch on the Offline unit, a switch is forced between
the two OCMs.
When depressed after an audible alarm is sounded, silences the alarm.
When depressed after any other alarm is triggered, acknowledges alarm.
Provides menu access via RS-232 (Craft) port on the front panel.
Connects to VT100 compatible terminal using a DB-9 serial cable.
Requires setting VT100 terminal emulation (to 9600, 19200, 38400, 57600, or 115200 bps), 8 Data Bits,
No Parity, 1 Stop Bit, and No Flow Control. (The baud rate default is 9600 bps, which can be
modified through the VT100 menu system.
Provides access to both OCMs installed in the chassis with connection to either OCM craft port.
NOTE: The OPTI-3 is an LR (long reach) optical product. When interfacing with IR (intermediate
reach) 3rd party equipment, the optical receive signal may need to be padded to avoid
overloading the optical receive signal. The receive signal level should be within 8 dbm to
28 dbm for IR equipment.
ADTRAN will replace or repair this product within the warranty period if it does not meet its published
specifications or fails while in service. Warranty information can be found at www.adtran.com/warranty.
U.S. and Canada customer Faxback: 877-457-5007, Document 414.
JOB
In-Service
Unit is Out-of-Service – Unassigned
from switching
Unit has an equipment failure
Normal Operation
Soft failure (e.g. RDI)
LOS, LOL, and other hard alarms on optical interface
Unit in Test (e.g. Loopback) with an alarm present on the Optical
Interface
Unit is ONLINE (DS3 TX ON)
Soft failure (e.g. RDI)
LOS, LOL, and other hard alarms on DS3 interface
Unit in Test (e.g. Loopback) with an alarm present on the DS3
Interface
When displayed on the OCM at the CO, indicates acknowledged
active alarms at the RT
edged active alarms at the RT
Acknowledged alarms active on the shelf
Unacknowledged alarms active on the shelf
A
ID

Advertisement

loading

Summary of Contents for ADTRAN Total Access OPTI-3 CPE OPTI-3 CPE

  • Page 1 The receive signal level should be within 8 dbm to 28 dbm for IR equipment. ADTRAN will replace or repair this product within the warranty period if it does not meet its published specifications or fails while in service. Warranty information can be found at www.adtran.com/warranty.
  • Page 2 CO craft port or the CO Ethernet LAN (via Telnet). This remote management is carried over the DCC section on the fibers between the OCMs. This mode of operation supports remote management of other ADTRAN equipment subtended from the OCM at the remote site. TFTP and SNMP are supported in this mode, both on a local Ethernet access and to the remote OCM.