Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions,
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Refer to
instruction
manual
1. SAFETY
1.1.
Electrical Safety
WARNING! It is the user's responsibility to check the following:
Check all electrical equipment and appliances to ensure that they are safe before using. Inspect power supply leads, plugs and
all electrical connections for wear and damage. Sealey recommend that an RCD (Residual Current Device) is used with all electrical
products. You may obtain an RCD by contacting your local Sealey stockist.
If the light is used in the course of business duties, it must be maintained in a safe condition and routinely PAT (Portable Appliance
Test) tested.
Electrical safety information, it is important that the following information is read and understood.
9
Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply.
9
regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure.
9
Ensure that the voltage rating on the appliance suits the power supply to be used and that the plug is fitted with the correct fuse.
9
DO NOT pull or carry the appliance by the power cable.
8
DO NOT pull the plug from the socket by the cable.
8
DO NOT use worn or damaged cables, plugs or connectors.
8
This product is fitted with a BS1363/A 13 Amp 3 pin plug. If the cable or plug is damaged during use, switch the electricity supply and
9
remove from use. Repairs must be carried out by a qualified electrician.
Replace a damaged plug with a BS1363/A 13 Amp 3 pin plug.
a) Connect the GREEN/YELLOW earth wire to the earth terminal 'E'.
b) Connect the BROWN live wire to the live terminal 'L'.
c) Connect the BLUE neutral wire to the neutral terminal 'N'.
Ensure that the total load on the sockets DOES NOT exceed 13A (this should include the load of the
9
light itself).
9
Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight.
9
Sealey recommend that repairs are carried out by a qualified electrician.
1.2.
General Safety
WARNING! Turn off the mains power supply before servicing or performing any maintenance.
Ensure the light is installed correctly in accordance with these instructions.
9
If you use an extension lead the cable must be fully unwound from the drum.
9
DANGER! DO NOT direct the light into a person's eyes. All models have a very intense light output which,
if incorrectly used, could cause eye damage.
DO NOT use the light near flammable, combustible or explosive liquids, solids, gases or equipment.
8
Maintain the light in good condition. Repairs must only be undertaken by a qualified electrician (use an authorised service agent).
9
Locate the light in an adequate area for its function, keep area clean and tidy and free from unrelated materials.
9
When not in use, switch off the light and disconnect from the power supply. Ensure that the unit is cool and dry and then store in a safe,
9
dry, childproof area.
2. INTRODUCTION
Heavy duty robust design with integral carry handle and 180° stand for positioning of light and substantial stability. SMD LED technology sitelight
for ultra bright illumination. Features 2 x 13A power sockets on reverse of light allowing other power tools to be used. Simple on/off weatherproof
switch on reverse of light. Cable strap to keep cable tidy when not in use. Cable gland fitted to entry of the light to provide good protection of the
cable. Supplied with BS approved 13A plug.
3. SPECIFICATION
Model No: .................................................... LED48230
Led Quantity: ................................................ 120 SMD
Lumen Output: ............................................. 5000lm
Supply: ......................................................... 230V
Power: .......................................................... 48W
IP Rating: ..................................................... IP54
Weight: ......................................................... 2.7kg
© Jack Sealey Limited
SITELIGHT 48W SMD LED WITH 2 X 13A
SOCKETS 230V
LED48230
MODEL NO:
Original Language Version
REPLACEMENT
FUSE: 13A
LED48230 Issue:1 07/06/18

Advertisement

loading

Summary of Contents for Sealey LED48230

  • Page 1 LED48230 MODEL NO: Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2 Important: No Liability is accepted for incorrect use of this product. Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim. Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR 01284 757500 01284 703534 sales@sealey.co.uk...