Scan Discard Partial Sequence to discard partial sequences when the
output sequence operation is terminated before completion. Scan Trans-
mit Partial Sequence to transmit partial sequences. (Any fields in the
sequence where no data match occurred will be skipped in the output.)
Transmit Partial Sequence
Require Output Sequence
When an output sequence is Required, all output data must conform to an
edited sequence or the sled will not transmit the output data to the host
device. When it's On/Not Required, the sled will attempt to get the output
data to conform to an edited sequence but, if it cannot, the sled transmits
all output data to the host device as is.
When the output sequence is Off , the bar code data is output to the host as
the sled decodes it. Default = Off.
Note: This selection is unavailable when the Multiple Symbols Selection is
turned on.
Required
Multiple Symbols
When this programming selection is turned On, it allows you to read multiple
symbols with a single pull of the trigger. If you press and hold the trigger, aiming
at a series of symbols, it reads unique symbols once, beeping (if turned on) for
*Off
* Discard Partial Sequence
On/Not Required
2 - 9