NSM–3/3D
PAMS Technical Documentation
Tuning Instructions
6. Energy Management Calibration
See section "Tuning – Energy Management Calibration... command" for
further information.
NOTE: This Calibration must be done when N100, N101 or a discrete
component affecting these two is changed.
Before battery a/d tuning is started a voltage setting request is shown to
user (Set supply voltage to 10,5 V). Service Battery is in this case JBU–6.
NOTE: Set DC Supply Mode in JBU–6 in FLA–5 (FLA–5/7) position!
Remember to connect SCB–3 cable between Service Box JBU–6!
When external power is connected and user selects Yes to continue, the
application displays the Energy Management Calibration dialog box:
E Nokia Mobile Phones Ltd.
Page 21
Issue 4 02/2002