6.1.4

Power Supply Functions:

- Power on Reset
To guarantee a defined startup, the ASIC will be reset by a Power on Reset block.
After Power on Reset the
be reached during operating mode the reset will become the device enters the power
down mode. This blocks are always active and will be supplied by VDDREF.
- Switch on and watchdog
There are 3 different possibilities to switch on the phone via external pins:
-VDD_CHARGE
-ON/OFF
with falling edge
-ON/OFF2
with rising edge
In order to guarantee a defined start-up behavior of the external components, a
sequential power up is used and the correct start up of blocks is supervised. In normal
mode, a continues watchdog signal from the µC is needed to keep the system
running. If this signals fails, the
It must be guaranteed, that each start up condition does not interfere and block the
other possible start up signals. In case of failure during start up, the device will go
back to power down mode. To guarantee that the connection of the a charging unit
with a very low battery is detected, this detection must work level sensitive at the end
of POR signal.
V1.00
S55/S57
ASIC
will enter the power done Mode. If the thresholds will
with rising edge
ASIC
will switch to power down mode.