RH-53/54
Nokia Customer Care
By measuring with an oscilloscope at RXIP or RXQP on a working GSM1900 receiver this pic-
ture should be seen
Signal amplitude peak-peak 588 mV
DC offset 1.33
Figure 33:Measuring with the oscilloscope
ISSUE 1 09/2004
COMPANY CONFIDENTIAL
45
Copyright © 2004 Nokia. All Rights Reserved.