BELL SYSTEM PRACTICES
AT&TCo Standard
I.
GENERAL
This section contains connection and maintenance
1 .01
information for 636CA (18-button) and 637DA
(30-button) CALL DIRECTOR® telephone sets
equipped with headset jacks.
This section is reissued to:
1.02
Revise 3.03
Add information on D-180463 Kit of Parts,
2.08 and Fig. 3
2.
CONNECTIONS
These sets are factory-wired for use with
2.01
1A1, 1A2, or 6A KTS line circuits.
may also be used with 1A KTS line circuits by
modifying the set as shown in Table A and B.
Line circuits for 1A, 1A1, or 1A2 KTS may be
connected to the same set under the following
conditions:
(a)
1A1 or 1A2 KTS lines must be connected
to the first key units with 1A lines connected
to supplementary key modules.
(b) 1A, 1A1, or 1A2 KTS lines should not be
connected to the same 6 line key module.
(c)
1A, 1A1, or 1A2 KTS lines appearing behind
a m a n u a l s w i t c h b o a r d s h o u ld n o t b e
intermixed o n a CALL DIRECTOR telephone set
due to the different time out intervals provided
by the associated KTU's.
The 636CA and 637DA sets are equipped
2.02
with a 635A5C (5-line pickup and hold) or
635AD5C (4-line pickup, cutoff, and hold) key in
the first module position. Contact strip assemblies
[required with sets equipped with a D120K (MD)
or D200S (MD) mounting cord]
two keys.
If ordered for field replacement, the
635AD5C is furnished with a piggy-back adapter
to which the slate mounting cord plug is connected.
The necessary contact strip assemblies (840151039
BSP 502-610-418-i04_1975-03-0l.jpg
Scanned by Frank Harrell, (Cowboy Frank) Castle Rock, Colorado
SERVICE
636CA AND 637DA TELEPHONE SETS
They
differ between the
©
American Telephone and Telegraph Company,
Printed in U.S.A.
Feb 04,2012 14:33:52
and 840151047) will be shipped with the 635AD5C
key, and will replace the 840151120 and 840151138
assemblies supplied with the 635A5C key.
Because of the physical arrangement of the
2.03
635-type key, the contact strips do not extend
to the chaining switch.
and ring to each module (except the last).
Fig. 2, sheets 1 through 5.
Mounting cords of these CALL DIRECTOR
2.04
sets terminate in individual plugs connected
to the rear of the keys. This permits rearrangement
of line appearance either in the set or at the key
equipment distribution point.
sets are equipped with a satin-silver ( -87) mounting
cord.
All line key positions are convertible to
2.05
signaling or common signaling arrangements
by removing the P-28E773 screw detail from key
positions involved and making the necessary wiring
changes per Table C.
These sets are not intended for use with
2.06
3-type speakerphone systems.
The 636CA and 637DA telephone sets are
2.07
factory-equipped with a KS-20419L1 (10 volt
AC only) buzzer.
When station busy lamp feature is required
2.08
with these sets having 1A1 or 1A2 KTS line
circuits, there are two optional circuits available.
The busy lamp(s) will light whenever a line pickup
button is depressed and the handset is off-hook or
the headset is plugged into the jacks. This optional
equipment must be ordered separately.
than one busy lamp is required, a 6C KTU must
be connected as shown in Fig. 5.
busy lamp, •install a D-180463 Kit of Parts (ordered
separately), consisting of a P-90D033 Printed Wiring
Board Assembly and 840361836 plug assembly (light
beige)..
Connect kit of parts as shown in Fig. 3.
1975
SECTION 502-610-418
Issue 4, March 1975
This requires a second tip
See
Current production
If more
For a single
Page
I

Advertisement

loading

Summary of Contents for AT&T 636CA

  • Page 1 (b) 1A, 1A1, or 1A2 KTS lines should not be connected to the same 6 line key module. The 636CA and 637DA telephone sets are 2.07 factory-equipped with a KS-20419L1 (10 volt 1A, 1A1, or 1A2 KTS lines appearing behind AC only) buzzer.
  • Page 2: Maintenance

    SECTION 502-61 0-418 Install the wiring board and plug assembly as Disconnect all mounting cord plugs and the follows: two contact strips [sets equipped with D120K (MD) or D200S (MD) mounting cords] from the Remove set housing. second module, remove key and replace with 635A5C key.
  • Page 3 T<RM I(R T<R M I NALS AR< ON T<RM BOARD 422BF 40108 OR NETWORK 2416 AMPllfi(R Fig. 1-636CA and 637DA Telephone Set, Connections Page 3 Scanned by Frank Harrell, (Cowboy Frank) Castle Rock, Colorado Feb 04,2012 14:35:12 502-610-418-i0 4_1975-03-03.j pg...
  • Page 4 SECTION 502-610-418 Notes for Fig. 2: I, THE 635AD5C KEY IS SUPPLIED WITH AN ADAPTER IN THE CUTOFF KEY POS I TION, THE SLATE MOUNTING CORD PLUG CONNECTS TO THE ADAPTER. CONNECT (BL·Y) ANO (Y·BL) ADAPTER LEADS TO TERMI NALS AND 2, RESPECT I VELY.
  • Page 5 1ST MODULE 636CA OR 637DA 8 OR Bt R R1 HOLD A H S OR Sl (BK-G) (BR-BK) A H S OR�I (R-S) (R-S) 0-BK IAI,IA2 BK-0 "" .. (R-0) {W-BR) A,H,S, OR Sl (W-BL) OR B "' !" ONLY A75A "'...
  • Page 6 � � � * � � � � � rROM TO SH 3-6370A TO SH 5-636CA Fig. 2-Module and Connector Cable Arrangements (Sheet 2 of S) Scanned by Frank Harrell, (Cowboy Frank) Castle Rock, Colorado Feb 04, 2012 14:36:17 502-610-418-i04_1975..03..06.jpg...
  • Page 7 CONNECTOR CAAL[ 02005 OR 0200AA FROM I 000 NOER MOUNTING (G-W) 3RO MODULE (NOTE 7) CORD (G) 6370,6, CON N 3 BIND ER (BR-Y) SPARE SPAR£ 635GSC SPARE '" { Y-B � {Y-BL) {BK-G) {BK-G) BR-BK BK-BR (R·S) (R·S) BL-BK TO lA, IAI,IA2 Of! 6A...
  • Page 8 "' MODULE 6370A FROM SH 3 02005 0200AA 4 TH AIOOD CONNECTOR MOUNTING CORD (BAl (ABLE ..BINDER (BR-W BINDER "' PLUG 4 CONN 4 SPARE SPARE SPARE 6 3 5G5C (NOTE 2l �� .,,. SPARE K( Y KE Y BL-Y ""...
  • Page 9 HOOUL£-636CA,Shl HOOULE-6370A FROM OR 4 )<IQUNT I NG CORD CONNECTOR CABLE BINDER A 7 5A· (G-W)B I NOER � 01< 0� 0120M 0200AA { BINDER A I 000-(S-W )8 I NOER 02:005 PLUG OR 5 SPAR( (NOTE7) G)T(5)0R SPARE 635G5C...
  • Page 10 CONTROL CIRCUIT SHOWN IN FIG.5 MAY BE B40361836 PLUG ASSEMBLY LEADS, USED. P/0 D-180463 KIT OF PARTS Fig. 3-+Statian Busy lamp Circuit Using Printed Wiring Board Assembly. TABLE A AI, AND 1A2 CONVERSION- 636CA TELEPHONE SET LEAD CONTACT STRIP LINE CHAINING PLUG HOLD KEY...
  • Page 11 ISS 4, SECTION 502-610-418 1ST HOLD ( O - W ) (W-0) (0-SK) (W-0) 20 (G-V) �6>-+--< 5 INSULATED AND STORED USE 0- 1 6 1488 CONNECTOR OR S PARE TERMINAL LEADS INVOLVED IN MODIFICATION FROM (0) BINDER -LINE S WITCH P ICKUP -CHAINING Fig.
  • Page 12 SECTION S02-610-418 TABLE B 1A, 1A1, AND 1A2 CONVERSION - 637DA TELEPHONE SET LEAD LINE CONTACT STRIP HOLD KEY CHAINING PLUG MODULE OR PLUG ARRANGE- MENT BR-V V-BR • • 1A1/1A2 Only 1A1/1A2- 1st, 2nd, 3rd, 4th, Mod 1A-5th Mod 1A1/1A2- 1st, 2nd, 3rd Mod...
  • Page 13 If more than five private or intercom lines are required, convert keys in 2nd (636CA) or 4th (637DA) module in same order. Connect plug leads to terminal 39 to utilize common signal key. If additional terminals are required, use any spare terminal and strap to 39.
  • Page 14 SECTION 502-61 0-418 TABLE CUT OFF KEY (635AD5C) CONNECTIONS 635AD5C MOUNTING CONNECTOR CABLE PLACE CORD RINGER FEATURE (BL-WI BINDER STRAP ADAPTER (BL) BINDER BK-G BL-Y Y-BL BL-Y Y-BL G·BK BK-BR Cutoff Ringer in TB1-1 Note 2 TB1-1 (Net.) TB1-2 Set (Note 1) TB1-2 Cutoff Ext Ringer or...

This manual is also suitable for:

637da