Loopback Control Codes; Table A-1. Loopback And Control Codes - ADTRAN QDFR Unit Installation And Maintenance Practice

Quad fiber remote (qdfr) unit
Table of Contents

Advertisement

Quad Fiber Remote (QDFR) Unit Installation and Maintenance Practice

Loopback Control Codes

A summary of control sequences is given in
of 5 seconds to be detected and acted upon.
In all control code sequences presented, the in-band codes are
shown left-most bit transmitted first, and the ESF data link codes
with right-most bit transmitted first.
Pattern
Description
1in3
Loopdown QDFC and QDFR and disarm
3in7
QDFR DS1 loopback to network
4in7
QDFC DS1 loopback to network
5in7
QDFR DS1 loopback to customer
6in7
QDFC DS1 loopback to customer
3F1E
QDFC DS1 loopback to customer
3F02
QDFR DS1 loopback to customer
3F02
QDFR DS1 loopback to customer
FF1E
QDFC loopback to network
Will not loopup QDFC if QDFC already in loopback to customer
FF02
QDFR loopback to network
Will not loopup QDFR if any unit already in loopback to customer
2in5
Arm QDFC and QDFR. QDFR DS1 will loopup (toward Network only) if
NIU LB is enabled
3in5
Disarm and loopdown QDFC and QDFR
Restores Loopback Timeout Override after D5D6
D3D3
QDFC DS1 loops up toward pattern: 2 seconds AIS, 5 seconds data,
then 231 bit errors toward pattern. 231 bit errors every 20 seconds as
long as the pattern is present
C742
QDFR DS1 loops up toward pattern: 2 seconds AIS, 5 seconds data,
and then 20 bit errors toward pattern. 20 errors every 20 seconds as
long as pattern present
A-2
Table
NOTE

Table A-1. Loopback and Control Codes

A-1. All codes must be sent for a minimum
Source
Arming
Required
NET
No
CUST
NET
No
NET
No
CUST
No
CUST
No
CUST
No
CUST
No
NET
Yes
NET
No
NET
No
NET
No
CUST
NET
No
CUST
NET
Yes
CUST
NET
Yes
CUST
61181307L7-5E