Table 4 includes the descriptions and values for the RX RF troubleshooting test points
shown in Figure 29.
Test
Point
1
2
3
4
5
6
7
Receiver IF
6
1
Issue 1 08/2004
6015/6015i/6016i/6019i (RH-55), 6012 (RM-20)
Table 4: Receiver RF Troubleshooting Values
Description
RX LO (from VCO)
Cell Channel 384 (from duplexer)
Cell Channel 384 (to RF SAW)
PCS Channel 600 (from duplexer)
PCS Channel 600 (to RF SAW)
IF MIX OUT (from Alfred)
IFA IN (to Alfred)
Figure 30: Receiver IF troubleshooting test points
©2004 Nokia Corporation
Troubleshooting - RF
Value
1009.62MHz at -8 dBm
2088.1MHz at -14 dBm
881.52MHz at -31 dBm
881.52MHz at -20 dBm (HG)
881.52MHz at -36 dBm (LG)
1960MHz at -40 dBm
1960MHz at -30 dBm (HG)
1960MHz at -45 dBm (LG)
128.1MHz at -20 dBm (HG)
128.1MHz at -37 dBm (LG)
128.1MHz at -15 dBm (HG)
128.1MHz at -30 dBm (LG)