BTL7-A/C/E/G50_-M_ _ _ _ -T_2/3-S32/S135/KA_ _/FA_ _
Magnetostrictive Linear Position Sensor - Rod Style
6
Configuration with the BTL7 Configuration Tool (continued)
6.3
Configuration options
Prerequisites
-
USB communication box connected to the BTL and
PC.
-
Software correctly installed.
-
BTL connected to the power supply.
-
Magnet on BTL.
Output functions
-
Position: Position in the measuring range.
-
Velocity: velocity of the magnet. The sign indicates the
direction of movement. Movement from the null point
to the end point is output with a positive sign.
Movement from the end point to the null point is output
with a negative sign. Max. detectable velocity range of
−10 to +10 m/s.
-
Velocity (no sign): velocity of the magnet. The
direction of movement cannot be read. Max.
detectable velocity range of 0 to 10 m/s.
Freely configurable curve
-
Null and end point can be read (teach-in) or specified
with the mouse.
-
For position, the distance between the null point and
end point must be at least 4 mm (0.15 inch) and
100 mm/s (4 inch/s) for velocity.
-
The characteristic curve can be inverted.
-
The limits can be adjusted to the measuring range.
-
The error value can be set in accordance with the
limits.
Output gradient
Rising
Falling
Tab. 6-1:
Factory settings value table
www.balluff.com
Null point
BTL
Unit
Min. value
V
−0.5
V
−10.5
V
+10.5
V
+10.5
20.4
20.4
Uncontrolled system movement
When starting up, if the position measuring system is
part of a closed loop system whose parameters have not
yet been set, the system may perform uncontrolled
movements. This could result in personal injury and
equipment damage.
► The system must be taken out of operation before
configuration.
► The BTLs may only be connected to the
communication box for configuration.
► The communication box must be removed after
configuration.
Null value
End value
0
+10
−10
+10
0
0
3.6
4
+10
+10
−10
20
20
DANGER
End point
Max. value
Error
value
+10.5
+10.5
+10.5
+10.5
20
20.4
20.4
20
20.4
3.6
0
−0.5
−0.5
−10.5
−10.5
0
0
20.4
4
3.6
3.6
english