SOFTWARE EVALUATION TOOL FOR S1C17602 S5U1C17602T1100 Software Manual...
Page 2
NOTICE No part of this material may be reproduced or duplicated in any form or by any means without the written permission of Seiko Epson. Seiko Epson reserves the right to make changes to this material without notice. Seiko Epson does not assume any liability of any kind arising out of any inaccuracies contained in this material or due to its application or use in any product or circuit and, further, there is no representation that this material is applicable to products requiring high level reliability, such as medical products.
Illuminance sensor (ADC) inspection..................8 Temperature/humidity sensor (RFC) inspection................9 Infrared inspection ........................9 5. Sample Application Specifications....................10 Use case configuration ......................10 Status transition between use cases ..................11 Use case scenarios ........................12 EPSON S5U1C17602T1100 Software Manual...
SVT17602 functions. These descriptions are not intended to assure the safety of the overall system architecture. 1.2 Related documents Refer to the S5U1C17001C Manual for detailed compiler specifications and discussions of how to use the GNU17 IDE. Refer to “SVT17602_HW_manual.pdf” for detailed SVT17602 CPU board specifications. EPSON S5U1C17602T1100 Software Manual...
[4] Program loading (1) Modify the path to fls17602.elf within the command file, if necessary. The default path is C:\EPSON\GNU17\mcu_model\17602\fls\fls17602.elf. Refer to the S5U1C17001C Manual for detailed information on modifying command files. (2) Use the IDE to load the “svt17602_sample” project.
ILLUMI Test Mode SW (port) test Inspects the SVT board. TEST MODE LCD test SVD test ADC test RFC test REMC test 3.2 Switches The SVT17602 CPU board switches shown below are used with sample applications. EPSON S5U1C17602T1100 Software Manual...
3.4 Function selection menu The following menu is displayed on the LCD panel 14SEG. Rotate the rotary SW clockwise or counterclockwise to select from the menu. Press SW1 or the rotary SW to enter the menu selected. EPSON S5U1C17602T1100 Software Manual...
Adjust minutes using the rotary SW in the same way as for hours. Press SW1 or the rotary SW to confirm minutes, then proceed to set seconds. Adjust seconds using the rotary SW. Press SW1 or the rotary SW to confirm seconds. Once, hours, minutes, and seconds have been set, the display will automatically revert to Time display (TIME). EPSON S5U1C17602T1100 Software Manual...
Press SW2 to return to the function selection menu display. 3.8 Illuminance [ILLUMI] 3.8.1 Illuminance measurement This function displays illuminance converted input from an illuminance sensor. Illuminance measurement continues until the operator presses SW2. Press SW2 to return to the function selection menu display. EPSON S5U1C17602T1100 Software Manual...
Press SW1 as indicated on the LCD. The program proceeds to the SW2 inspection once the SW1 input has been correctly detected. Inspect SW2 and the rotary SW in the same way. LCD panel inspection begins once switch inspection is complete. EPSON S5U1C17602T1100 Software Manual...
This inspection confirms that the input from the illuminance sensor is correctly A/D converted and that the illuminance is correctly displayed. [Inspection method] Confirm that the illuminance value displayed on the panel varies when the light level is altered. Following confirmation, press SW2 to start temperature/humidity sensor inspections. EPSON S5U1C17602T1100 Software Manual...
A: “REMC OK” B: “TRANS END” If “REMC OK” is displayed for A after remote control transmission and reception is complete, the inspection is complete. This completes all inspections. Press SW2 to return to the menu. EPSON S5U1C17602T1100 Software Manual...
UC64: Inspect infrared REMC UC65: Inspect illuminance sensor UC66: Inspect temperature/humidity sensors UC71: Measure temperature/humidity * Ports for switch input and LCD panels can also be regarded as actors, but they are grouped with the operators here. EPSON S5U1C17602T1100 Software Manual...
Describes alternate flow details in chronological order. The description is the same as for the basic flow. Alternate flows are numbered “3a,” “3b,” etc. if there are multiple transitions from the basic flow. Conditions for transition from basic flow 4. --- Remarks --- Other precautions and notes are described here. EPSON S5U1C17602T1100 Software Manual...
--- Remarks --- When this is rotated clockwise, the menus are displayed in the sequence 6 → 1 → 2… When this is rotated counterclockwise, menus are displayed in the sequence 1 → 6 → 5… EPSON S5U1C17602T1100 Software Manual...
If the time held internally advanced before the operator pressed SW2 *1 To basic flow 2 If SW1 and SW2 are pressed simultaneously “UC22: Set time” is called. --- Remarks --- The time held internally is updated each second by UC23: Advance time. EPSON S5U1C17602T1100 Software Manual...
The system calls “UC21: Display time.” (To UC21) --- Alternate flow --- If SW1 is not pressed, to basic flow 3 If SW1 is not pressed, to basic flow 7 If SW1 is not pressed, to basic flow 11 --- Remarks --- None EPSON S5U1C17602T1100 Software Manual...
Hours: Advanced in the sequence 00 → 01 → 02… → 23. After 23, reverts to 00. The system clears the 1 Hz interrupt and awaits the next 1 Hz interrupt. --- Remarks --- An 8 Hz interrupt is also used for rotary SW. EPSON S5U1C17602T1100 Software Manual...
The system restarts OSC3 and returns the system clock from OSC1 to OSC3. The system calls “UC12: Select function.” (To UC12) --- Alternate flow --- None --- Remarks --- Battery level is displayed as full (3), medium (2), low (1), empty (0). EPSON S5U1C17602T1100 Software Manual...
Counterclockwise: -1 The operator presses SW2 to return to function selection. The system calls “UC12: Select function.” (To UC12) --- Alternate flow --- If SW2 is not pressed To basic flow 2 --- Remarks --- None EPSON S5U1C17602T1100 Software Manual...
The system halts A/D conversion. The system calls “UC12: Select function.” (To UC12) --- Alternate flow --- If SW2 is not pressed, to basic flow 1 --- Remarks --- Results are updated using A/D conversion complete interrupt. EPSON S5U1C17602T1100 Software Manual...
The operator presses SW2 to return to function selection. The system halts R/F conversion. The system calls “UC12: Select function.” (To UC12) --- Alternate flow --- If SW2 is not pressed To basic flow 2 for re-measurement --- Remarks --- None EPSON S5U1C17602T1100 Software Manual...
No part of this material may be reproduced or duplicated in any form or by any means without the written permission of Seiko Epson. Seiko Epson reserves the right to make changes to this material without notice. Seiko Epson does not assume any liability of any kind arising out of any inaccuracies contained in this material or due to its application or use in any product or circuit and, further, there is no representation that this material is applicable to products requiring high level reliability, such as medical products.