4.4.4 Export Power Limit Connection Diagram
The methods of connecting the Power Limiting device CT is shown below.
For the detailed installation procedure of CT, please refer to Step 4 of 4.4.3.
White & Black Wire
CT
Black
Wire
L
Inverter
4.4.5 Earth Fault Alarm(Only for Australia and New Zealand)
In compliance with the section 13.9 of IEC62109-2, the GEP inverter is equipped with an
earth fault alarm. When earth fault occurs, the fault indicator at the front LED screen will light up. On
inverters with Wi-Fi communication, the system sends an email with the fault notification to the
customer. For inverters without Wi-Fi, the buzzer of the inverter will keep ringing for one minute and
ring again at 30-minute intervals until the fault is resolved. (This function is only available in Austra-
lia and New Zealand).
4.4.6 Monitoring Portal
Portal is an online monitoring system. After completing the installation of commu -
nication connection, you can access
portal.gesolarinverter.com
'Power Sight' App by scanning the QR code to monitor your PV plant and device.
Please contact after-sales for further details.
15
15
N
Switch Board
Router
or download the
5 System Operation
5.1 LCD Panel
Power
Yellow
Running
Green
Alarm
Red
Power Sight
ON=COMMUNICATION CONNECTED/ACTIVE
BLINK 1=COMMUNICATION SYSTEM RESETTING
BLINK 2=NOT CONNECT TO ROUTER
BLINK 4=COMMUNICATION SERVER PROBLEM
BLINK =RS485 CONNECTED
OFF=COMMUNICATION NOT ACTIVE
ON=INVERTER IS FEEDING POWER
OFF=INVERTER IS NOT FEEDING POWER AT THE MOMENT
ON=FAULT OCCURRED
OFF=NO FAULT
16
16