IF YOUR SMOKE/CO ALARM SOUNDS, Continued
POTENTIAL SOURCES OF CO IN THE HOME
THE "LATCHING ALARM" INDICATOR:
Fuel-burning appliances
like: portable heater,
The Latching Alarm Indicator is activated after an Alarm is exposed to
gas or wood burning
alarm levels of smoke or carbon monoxide. This feature will only work
fireplace, gas kitchen
with AC power. After smoke or CO levels drop below alarm levels, the
range or cooktop, gas
red smoke or CO LED will begin to flash once every 5 seconds. It will
clothes dryer.
continue to flash or "latch" until you clear it by testing the alarm.
Damaged or insufficient
This feature helps emergency responders, investigators, or service
venting: corroded or
technicians identify which unit(s) in your home were exposed to alarm
disconnected water
levels of smoke or carbon monoxide. This can help investigators
heater vent pipe, leaking
pinpoint the source of smoke or CO.
chimney pipe or flue, or
Interconnected Alarms. Latching Alarm Indicator shows which Alarm(s)
cracked heat exchanger,
in the series were exposed to alarm levels of smoke or carbon monoxide.
blocked or clogged
The Latching Alarm Indicator stays ON until you clear it, so it can alert
chimney opening.
you to an alarm that occurred while you were away from home, even
Improper use of appliance/device: operating a barbecue grill or
though smoke or CO present in the air has dropped below alarm levels.
vehicle in an enclosed area (like a garage or screened porch).

WEEKLY TESTING

Transient CO Problems: "transient" or on-again-off-again CO problems
can be caused by outdoor conditions and other special circumstances.
The following conditions can result in transient CO situations:
• NEVER use an open flame of any kind to test this unit. You
might accidentally damage or set fire to the unit or to your
1. Excessive spillage or reverse venting of fuel appliances caused by
home. The built-in test switch accurately tests the unit's
outdoor conditions such as:
operation as required by Underwriters Laboratories, Inc. (UL).
• Wind direction and/or velocity, including high, gusty winds. Heavy
If you choose to use an aerosol smoke product to test the
air in the vent pipes (cold/humid air with extended periods
Smoke Alarm, be certain to use one that has been Listed to
between cycles).
Underwriters Laboratories, Inc. Safety Standards, and use it
• Negative pressure differential resulting from the use of exhaust
only as directed. Use of non-UL Listed products or improper
fans.
use of UL Listed products may affect the Smoke Alarm's sen-
• Several appliances running at the same time competing for limited
sitivity, and may void your warranty. NEVER use vehicle
fresh air.
exhaust! Exhaust may cause permanent damage and voids
• Vent pipe connections vibrating loose from clothes dryers,
your warranty.
furnaces, or water heaters.
• DO NOT stand close to the Alarm when the horn is sounding.
• Obstructions in or unconventional vent pipe designs which can
Exposure at close range may be harmful to your hearing.
amplify the above situations.
When testing, step away when horn starts sounding.
2. Extended operation of unvented fuel burning devices (range, oven,
fireplace).
It is important to test this unit every week to make sure it is working
3. Temperature inversions, which can trap exhaust close to the ground.
properly. Using the test button is the recommended way to test this
4. Car idling in an open or closed attached garage, or near a home.
Smoke/CO Alarm.
These conditions are dangerous because they can trap exhaust in your
1. Push and hold the Test/Silence button on the cover until you hear a
home. Since these conditions can come and go, they are also hard to
"chirp." The "chirp" marks the start of the self-test sequence.
recreate during a CO investigation.
2. During testing, you will hear a loud, repeating horn pattern: 3 beeps,
pause, 3 beeps, pause, while the red smoke LED flashes. Then you
HOW CAN I PROTECT MY FAMILY FROM CO
will hear a loud, repeating horn pattern: 4 beeps, pause, 4 beeps,
POISONING?
pause, while the red CO LED flashes.
A CO Alarm is an excellent means of protection. It monitors the air
3. When testing a series of interconnected units you must test each
and sounds a loud alarm before Carbon Monoxide levels become
unit individually. Make sure all units alarm when each one is tested.
threatening for average, healthy adults.
If the Smoke/CO Alarm does not test properly:
A CO Alarm is not a substitute for proper maintenance of home
1. Make sure the AC power is applied and battery is fresh and installed
appliances.
correctly.
To help prevent CO problems and reduce the risk of CO poisoning:
2. Be sure the alarm is clean and dust-free.
• Clean chimneys and flues yearly. Keep them free of debris, leaves,
3. Test the unit again.
and nests for proper air flow. Also, have a professional check for
rust and corrosion, cracks, or separations. These conditions can
If the Smoke/CO Alarm is still not working properly, replace it immediately.
prevent proper air movement and cause backdrafting. Never
Refer to the "Limited Warranty" at the end of this manual.
"cap" or cover a chimney in any way that would block air flow.
• Test and maintain all fuel-burning equipment annually. Many local
If there is still a problem, do not try to fix the Alarm yourself. This will
gas or oil companies and HVAC companies offer appliance
void your warranty!
inspections for a nominal fee.
• Make regular visual inspections of all fuel-burning appliances.

REGULAR MAINTENANCE

Check appliances for excessive rust and scaling. Also check the
flame on the burner and pilot lights. The flame should be blue.
A yellow flame means fuel is not being burned completely and
Use only the replacement batteries listed below. The unit may not
CO may be present. Keep the blower door on the furnace closed.
operate properly with other batteries. Never use rechargeable
Use vents or fans when they are available on all fuel-burning
batteries since they may not provide a constant charge.
appliances. Make sure appliances are vented to the outside. Do
This unit has been designed to be as maintenance-free as possible, but
not grill or barbecue indoors, or in garages or on screen porches.
there are a few simple things you must do to keep it working properly:
• Check for exhaust backflow from CO sources. Check the draft
Test it at least once a week.
hood on an operating furnace for a backdraft. Look for cracks on
furnace heat exchangers.
Clean the Smoke/CO Alarm at least once a month; gently vacuum
• Check the house or garage on the other side of shared wall.
the outside of the Smoke/CO Alarm using your household vacuum's
soft brush attachment. Test the Smoke/CO Alarm. Never use water,
• Keep windows and doors open slightly. If you suspect that CO
cleaners or solvents since they may damage the unit.
is escaping into your home, open a window or a door. Opening
windows and doors can significantly decrease CO levels.
If the Smoke/CO Alarm becomes contaminated by excessive dirt,
dust and/or grime, and cannot be cleaned to avoid unwanted
In addition, familiarize yourself with all enclosed materials. Read
alarms, replace the unit immediately.
this manual in its entirety, and make sure you understand what to
Relocate the unit if it sounds frequent unwanted alarms. See "Where
do if your CO Alarm sounds.
This Alarm Should Not Be Installed" for details.
When the battery back-up becomes weak, the Alarm will "chirp"
REGULATORY INFORMATION FOR
about once a minute (the low battery warning). This warning should
SMOKE/CO ALARMS
last 7 days, but you should replace the battery immediately to con-
tinue your protection. This Alarm must have AC or battery power
REGULATORY INFORMATION FOR CO ALARMS
to operate. If AC power fails, and the battery is dead or missing,
the Alarm cannot operate.
WHAT LEVELS OF CO CAUSE AN ALARM?
Underwriters Laboratories Inc. Standard UL2034 requires residential CO
Alarms to sound when exposed to levels of CO and exposure times as
DO NOT spray cleaning chemicals or insect sprays directly on or near
described below. They are measured in parts per million (ppm) of CO
the Alarm. DO NOT paint over the Alarm. Doing so may permanently
over time (in minutes).
damage the Alarm.
UL2034 Required Alarm Points*:
CHOOSING A REPLACEMENT BATTERY:
• If the alarm is exposed to 400 ppm of CO, IT MUST ALARM
Your Smoke/CO Alarm requires one standard 9V battery. The following
BETWEEN 4 and 15 MINUTES.
batteries are acceptable as replacements: Duracell #MN1604, (Ultra)
• If the alarm is exposed to 150 ppm of CO, IT MUST ALARM
#MX1604; Eveready (Energizer) #522. You may also use a Lithium
BETWEEN 10 and 50 MINUTES.
battery like the Ultralife U9VL-J for longer service life between battery
• If the alarm is exposed to 70 ppm if CO, IT MUST ALARM
changes. These batteries are available at many local retail stores.
BETWEEN 60 and 240 MINUTES.
* Approximately 10% COHb exposure at levels of 15% to 95% Relative
Actual battery service life depends on the Smoke/CO Alarm and the
Humidity (RH).
environment in which it is installed. All the batteries specified above
are acceptable replacement batteries for this unit. Regardless of the
The unit is designed not to alarm when exposed to a constant level
manufacturer's suggested battery life, you MUST replace the battery
of 30 ppm for 30 days.
immediately once the unit starts "chirping" (the "low battery warning").
CO Alarms are designed to alarm before there is an immediate life

WHAT YOU NEED TO KNOW ABOUT CO

threat. Since you cannot see or smell CO, never assume it's not present.
WHAT IS CO?
An exposure to 100 ppm of CO for 20 minutes may not affect aver-
CO is an invisible, odorless, tasteless gas produced when fossil fuels do
age, healthy adults, but after 4 hours the same level may cause
headaches.
not burn completely, or are exposed to heat (usually fire). Electrical
appliances typically do not produce CO.
An exposure to 400 ppm of CO may cause headaches in average,
These fuels include: Wood, coal, charcoal, oil, natural gas, gasoline,
healthy adults after 35 minutes, but can cause death after 2 hours.
kerosene, and propane.
Standards: Underwriters Laboratories Inc. Single and Multiple Station
Common appliances are often sources of CO. If they are not properly
carbon monoxide alarms UL2034.
maintained, are improperly ventilated, or malfunction, CO levels can rise
According to Underwriters Laboratories Inc. UL2034, Section 1-1.2:
quickly. CO is a real danger now that homes are more energy efficient.
"Carbon monoxide alarms covered by these requirements are intended
"Air-tight" homes with added insulation, sealed windows, and other
to respond to the presence of carbon monoxide from sources such as,
weatherproofing can "trap" CO inside.
but not limited to, exhaust from internal-combustion engines, abnor-
mal operation of fuel-fired appliances, and fireplaces. CO Alarms are
SYMPTOMS OF CO POISONING
intended to alarm at carbon monoxide levels below those that could
These symptoms are related to CO POISONING and should be dis-
cause a loss of ability to react to the dangers of Carbon Monoxide
cussed with ALL household members.
exposure." This CO Alarm monitors the air at the Alarm, and is
Mild Exposure: Slight headache, nausea, vomiting, fatigue ("flu-like"
designed to alarm before CO levels become life threatening. This
symptoms).
allows you precious time to leave the house and correct the problem.
This is only possible if Alarms are located, installed, and maintained as
Medium Exposure: Throbbing headache, drowsiness, confusion, fast
described in this manual.
heart rate.
Gas Detection at Typical Temperature and Humidity Ranges: The CO
Extreme Exposure: Convulsions, unconsciousness, heart and lung
Alarm is not formulated to detect CO levels below 30 ppm typically.
failure. Exposure to Carbon Monoxide can cause brain damage, death.
Audible Alarm: 85dB minimum at 10 feet (3 meters).
This CO Alarm measures exposure to CO over time. It alarms if CO levels
REGULATORY INFORMATION FOR SMOKE ALARMS
are extremely high in a short period of time, or if CO levels reach a certain
minimum over a long period of time. The CO Alarm generally sounds an
RECOMMENDED LOCATIONS FOR SMOKE ALARMS
alarm before the onset of symptoms in average, healthy adults.
Installing Smoke Alarms in Single-Family Residences
Why is this important? Because you need to be warned of a potential
The National Fire Protection Association (NFPA), recommends one
CO problem while you can still react in time. In many reported cases of
Smoke Alarm on every floor, in every sleeping area, and in every bed-
CO exposure, victims may be aware that they are not feeling well, but
room. In new construction, the Smoke Alarms must be AC powered and
become disoriented and can no longer react well enough to exit the
interconnected. See "Agency Placement Recommendations" for details.
building or get help. Also, young children and pets may be the first
For additional coverage, it is recommended that you install a Smoke
affected. The average healthy adult might not feel any symptoms when
Alarm in all rooms, halls, storage areas, finished attics, and basements,
the CO Alarm sounds. However, people with cardiac or respiratory
where temperatures normally remain between 40˚ F (4˚ C) and 100˚ F
problems, infants, unborn babies, pregnant mothers, or elderly people
(38˚ C). Make sure no door or other obstruction could keep smoke from
can be more quickly and severely affected by CO. If you experience
reaching the Smoke Alarms.
even mild symptoms of CO poisoning, consult your doctor immediately!
More specifically, install Smoke Alarms:
FINDING THE SOURCE OF CO AFTER AN ALARM
On every level of your home, including finished attics and basements.
Carbon monoxide is an odorless, invisible gas, which often makes it
Inside every bedroom, especially if people sleep with the door partly
difficult to locate the source of CO after an alarm. These are a few of the
or completely closed.
factors that can make it difficult to locate sources of CO:
In the hall near every sleeping area. If your home has multiple
• House well ventilated before the investigator arrives.
sleeping areas, install a unit in each. If a hall is more than 40 feet
• Problem caused by "backdrafting."
long (12 meters), install a unit at each end.
• Transient CO problem caused by special circumstances.
At the top of the first-to-second floor stairway, and at the bottom of
the basement stairway.
Because CO may dissipate by the time an investigator arrives, it may
be difficult to locate the source of CO. BRK Brands, Inc. shall not be
obligated to pay for any carbon monoxide investigation or service
call.
7
RECOMMENDED LOCATIONS FOR SMOKE ALARMS, Continued
Specific requirements for Smoke Alarm installation vary from state to
state and from region to region. Check with your local Fire Department
for current requirements in your area. It is recommended AC or AC/DC
units be interconnected for added protection.
INSTALLING SMOKE ALARMS IN MOBILE HOMES &
RVS
For minimum security install one Smoke Alarm as close to each sleeping
area as possible. For more security, put one unit in each room. Many older
mobile homes (especially those built before 1978) have little or no insula-
tion. If your mobile home is not well insulated, or if you are unsure of the
amount of insulation, it is important to install units on inside walls only.
Smoke Alarms should be installed where temperatures normally remain
between 40˚ F (4˚ C) and 100˚ F (38˚ C). WARNING: Test units used in
RVs after the vehicle has been in storage, before every trip, and
once a week while in use. Failure to test units used in RVs as
described may remove your protection.
This equipment should be installed in accordance with NFPA (National Fire
Protection Association) 72 and 101. National Fire Protection Association,
One Batterymarch Park, Quincy, MA 02269-9101. Additional local build-
ing and regulatory codes may apply in your area. Always check com-
pliance requirements before beginning any installation.
AGENCY PLACEMENT RECOMMENDATIONS
NFPA 72 (National Fire Code)
Smoke Alarms shall be installed in each separate sleeping room, outside
each sleeping area in the immediate vicinity of the bedrooms and on each
additional story of the family living unit, including basements and exclud-
ing crawl spaces and unfinished attics.
In new construction, Alarms shall be so arranged that operation of any one
Alarm shall cause the operation of all Alarms within the dwelling.
Smoke Detection-Are More Smoke Alarms Desirable? The required
number of Smoke Alarms might not provide reliable early warning
protection for those areas separated by a door from the areas protected
by the required Smoke Alarms. For this reason, it is recommended that
the householder consider the use of additional Smoke Alarms for those
areas for increased protection. The additional areas include the base-
ment, bedrooms, dining room, furnace room, utility room, and hallways
not protected by the required Smoke Alarms. The installation of Smoke
Alarms in kitchens, attics (finished or unfinished), or garages is not nor-
mally recommended, as these locations occasionally experience condi-
tions that can result in improper operation.
California State Fire Marshal (CSFM)
Early warning detection is best achieved by the installation of fire detec-
tion equipment in all rooms and areas of the household as follows: A
Smoke Alarm installed in each separate sleeping area (in the vicinity, but
outside bedrooms), and Heat or Smoke Alarms in the living rooms, dining
rooms, bedrooms, kitchens, hallways, finished attics, furnace rooms,
closets, utility and storage rooms, basements, and attached garages.
ABOUT SMOKE ALARMS
Battery (DC) operated Smoke Alarms: Provide protection even when
electricity fails, provided the batteries are fresh and correctly installed.
Units are easy to install, and do not require professional installation.
AC powered Smoke Alarms: Can be interconnected so if one unit
senses smoke, all units alarm. They do not operate if electricity fails.
AC with battery (DC) back-up: will operate if electricity fails, provided
the batteries are fresh and correctly installed. AC and AC/DC units
must be installed by a qualified electrician.
Smoke Alarms for Solar or Wind Energy users and battery backup
power systems: AC powered Smoke Alarms should only be operated
with true or pure sine wave inverters. Operating this Smoke Alarm with
most battery-powered UPS (uninterruptible power supply) products or
square wave or "quasi sine wave" inverters will damage the Alarm. If
you are not sure about your inverter or UPS type, please consult with
the manufacturer to verify.
Smoke Alarms for the hearing impaired: Special purpose Smoke
Alarms should be installed for the hearing impaired. They include a visu-
al alarm and an audible alarm horn, and meet the requirements of the
Americans With Disabilities Act. These units can be interconnected so if
one unit senses smoke, all units alarm.
All these Smoke Alarms are designed to provide early warning of fires if
located, installed and cared for as described in the user's manual, and if
smoke reaches the Alarm. If you are unsure which type of unit to install,
refer to NFPA (National Fire Protection Association) 72 (National Fire
Alarm Code) and NFPA 101 (Life Safety Code). National Fire Protection
Association, One Batterymarch Park, Quincy, MA 02269-9101. Local
building codes may also require specific units in new construction or in
different areas of the home.
SPECIAL COMPLIANCE CONSIDERATIONS
This unit alone is not a suitable substitute for complete fire detec-
tion systems in places housing many people—like apartment build-
ings, condominiums, hotels, motels, dormitories, hospitals, long-
term health care facilities, nursing homes, day care facilities, or
group homes of any kind—even if they were once single-family
homes. It is not a suitable substitute for complete fire detection
systems in warehouses, industrial facilities, commercial buildings,
and special-purpose non-residential buildings which require special
fire detection and alarm systems. Depending on the building codes
in your area, this unit may be used to provide additional protection
in these facilities.
The following information applies to all four types of buildings listed
below:
In new construction, most building codes require the use of AC or
AC/DC powered Smoke Alarms only. AC, AC/DC, or DC powered
Smoke Alarms can be used in existing construction as specified by local
building codes. Refer to NFPA 72 (National Fire Alarm Code) and NFPA
101 (Life Safety Code), local building codes, or consult your Fire
Department for detailed fire protection requirements in buildings not
defined as "households."
1. Single-Family Residence:
Single family home, townhouse. It is recommended this unit be installed
on every level of the home, in every bedroom, and in each bedroom
hallway.
2. Multi-Family or Mixed Occupant Residence:
Apartment building, condominium. This unit is suitable for use in individ-
ual apartments or condos, provided a primary fire detection system
already exists to meet fire detection requirements in common areas like
lobbies, hallways, or porches. Using this unit in common areas may not
provide sufficient warning to all residents or meet local fire protection
ordinances/regulations.
3. Institutions:
Hospitals, day care facilities, long-term health care facilities. This unit is
suitable for use in individual patient sleeping/resident rooms, provided a
primary fire detection system already exists to meet fire detection
requirements in common areas like lobbies, hallways, or porches. Using
this unit in common areas may not provide sufficient warning to all resi-
dents or meet local fire protection ordinances/regulations.
4. Hotels and Motels:
Also boarding houses and dormitories. This unit is suitable for use
inside individual sleeping/resident rooms, provided a primary fire detec-
tion system already exists to meet fire detection requirements in com-
mon areas like lobbies, hallways, or porches. Using this unit in common
areas may not provide sufficient warning to all residents or meet local
Continued...
fire protection ordinances/regulations.
8
9
GENERAL LIMITATIONS OF SMOKE/CO ALARMS
This Smoke/CO Alarm is intended for residential use. It is not intended
minimum protection is one alarm device in every sleeping area, every
for use in industrial applications where Occupational Safety and Health
bedroom, and on every level of your home. Some experts recommend
Administration (OSHA) requirements for Carbon Monoxide Alarms must
battery powered Smoke and CO Alarms be used in conjunction with
be met. The Smoke Alarm portion of this device is not intended to alert
interconnected AC powered Smoke Alarms. For details, see "About
hearing impaired residents. Special purpose Smoke Alarms should be
Smoke Alarms" for details.
installed for hearing impaired residents (CO Alarms are not yet available
Smoke/CO Alarms may not be heard. The alarm horn loudness
for the hearing impaired).
meets or exceeds current UL standards of 85dB at 10 feet (3 meters).
Smoke/CO Alarms may not waken all individuals. Practice the
However, if the Smoke/CO Alarm is installed outside the bedroom, it
escape plan at least twice a year, making sure that everyone is involved
may not wake up a sound sleeper or one who has recently used drugs
– from kids to grandparents. Allow children to master fire escape
or has been drinking alcoholic beverages. This is especially true if the
planning and practice before holding a fire drill at night when they are
door is closed or only partly open. Even persons who are awake may
sleeping. If children or others do not readily waken to the sound of the
not hear the alarm horn if the sound is blocked by distance or closed
Smoke/CO Alarm, or if there are infants or family members with mobility
doors. Noise from traffic, stereo, radio, television, air conditioner, or
limitations, make sure that someone is assigned to assist them in fire
other appliances may also prevent alert persons from hearing the alarm
drill and in the event of an emergency. It is recommended that you hold
horn. This Smoke/CO Alarm is not intended for people who are hearing
a fire drill while family members are sleeping in order to determine their
impaired.
response to the sound of the Smoke/CO Alarm while sleeping and
The Alarm may not have time to alarm before the fire itself causes
to determine whether they may need assistance in the event of an
damage, injury, or death, since smoke from some fires may not
emergency.
reach the unit immediately. Examples of this include persons smok-
Smoke/CO Alarms cannot work without power. Battery operated units
ing in bed, children playing with matches, or fires caused by violent
cannot work if the batteries are missing, disconnected or dead, if the
explosions resulting from escaping gas.
wrong type of batteries are used, or if the batteries are not installed cor-
This Smoke/CO Alarm is not a substitute for life insurance.
rectly. AC units cannot work if the AC power is cut off for any reason (open
Though this Smoke/CO Alarm warns against increasing CO levels or the
fuse or circuit breaker, failure along a power line or at a power station,
presence of smoke, BRK Brands, Inc. does not warrant or imply in any
electrical fire that burns the electrical wires, etc.). If you are concerned
way that they will protect lives. Homeowners and renters must still
about the limitations of battery or AC power, install both types of units.
insure their lives.
This Smoke/CO Alarm will not sense smoke or CO that does not
This Smoke/CO Alarm has a limited life. Although this Smoke/CO
reach the sensors. It will only sense smoke or CO at the sensor. Smoke
Alarm and all of its parts have passed many stringent tests and are
or CO may be present in other areas. Doors or other obstructions may
designed to be as reliable as possible, any of these parts could fail at
affect the rate at which CO or smoke reaches the sensors. If bedroom
any time. Therefore, you must test this device weekly. The unit should
doors are usually closed at night, we recommend you install an alarm
be replaced immediately if it is not operating properly.
device (Combination CO and Smoke Alarm, or separate CO Alarms and
Smoke Alarms) in each bedroom and in the hallway between them.
This Smoke/CO Alarm is not foolproof. Like all other electronic
devices, this Smoke/CO Alarm has limitations. It can only detect smoke
This Smoke/CO Alarm may not sense smoke or CO on another
or CO that reaches the sensors. It may not give early warning of the
level of the home. Example: This alarm device, installed on the second
source of smoke or CO is in a remote part of the home, away from the
floor, may not sense smoke or CO in the basement. For this reason,
alarm device.
one alarm device may not give adequate early warning. Recommended

TROUBLESHOOTING GUIDE

ELECTRICAL SHOCK HAZARD. Turn off the power to the area where the Alarm is installed BEFORE removing it from the mounting bracket or
checking any electrical connections! Failure to turn off the power first may result in serious electrical shock, injury or death.
If your Alarm does this...
It means...
Green light is OFF. Unit will not alarm when you
Unit may not be receiving any power.
press the Test/Silence button.
Green light flashes ON, once a minute (horn is
Alarm is not receiving AC power.
silent).
Once a minute, the Green light flashes and the
Low battery warning. Battery is low or missing.
horn "chirps".
Once a minute, the alarm sounds 3 quick
Unit malfunction. Unit needs to be replaced.
"chirps", and the green light flashes quickly
Based on self-diagnostic tests, the unit has
three times.
detected a fault.
Alarm goes back into alarm after you pressed
Smoke and/or CO levels are still potentially
the Test/Silence button to silence an alarm.
dangerous.
Alarm sounds frequently even though no high
The Alarm may be improperly located. Refer to
levels of smoke or CO are revealed in an
"Where to Install This Alarm."
investigation.
*For a list of acceptable replacement batteries, see "Regular Maintenance."
If you have any questions that cannot be answered by reading this manual, call Consumer Affairs: 1-800-323-9005.

LIMITED WARRANTY

BRK Brands, Inc., ("BRK") the maker of BRK
®
brand and First Alert
®
brand products, warrants that for a period of five years from the date of purchase,
this product will be free from defects in material and workmanship. BRK, at its option, will repair or replace this product or any component of the product
found to be defective during the warranty period. Replacement will be made with a new or remanufactured product or component. If the product is no
longer available, replacement may be made with a similar product of equal or greater value. This is your exclusive warranty.
This warranty is valid for the original retail purchaser from the date of initial retail purchase and is not transferable. Keep the original sales receipt.
Proof of purchase is required to obtain warranty performance. BRK dealers, service centers, or retail stores selling BRK products do not have the right to
alter, modify or any way change the terms and conditions of this warranty.
This warranty does not cover normal wear of parts or damage resulting from any of the following: negligent use or misuse of the product, use on improper
voltage or current, use contrary to the operating instructions, disassembly, repair or alteration by anyone other than BRK or an authorized service center.
Further, the warranty does not cover Acts of God, such as fire, flood, hurricanes and tornadoes or any batteries that are included with this unit.
BRK shall not be liable for any incidental or consequential damages caused by the breach of any express or implied warranty. Except to the extent
prohibited by applicable law, any implied warranty of merchantability or fitness for a particular purpose is limited in duration to the duration of the above
warranty. Some states, provinces or jurisdictions do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long
an implied warranty lasts, so the above limitations or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have
other rights that vary from state to state or province to province.
How to Obtain Warranty Service
Service: If service is required, do not return the product to your retailer. In order to obtain warranty service, contact the Consumer Affairs Division at
1-800-323-9005, 7:30 AM - 5:00 PM Central Standard Time, Monday through Friday. To assist us in serving you, please have the model number and
date of purchase available when calling.
303 Nelson Avenue, Neosho, MO 64850-8806.
Battery: BRK Brands, Inc. make no warranty, express or implied, written or oral, including that of merchantability or fitness for any particular purpose
with respect to battery.
For your records, please record:
Date Purchased: ____________________________
Where Purchased: _____________________________________
BRK Electronics
First Alert
10
You should...
Check the AC power supply. Make sure the
power connector is securely attached to the
alarm. Make sure a fresh 9V battery is installed to
power the battery back-up*.
Unit is operating on battery back-up.
Check the AC power supply.
Replace the battery, avoid interrupting AC
power.
Units under warranty should be returned to
manufacturer for replacement. See "Limited
Warranty" for details.
Refer to "If Your Smoke/CO Alarm Sounds" for
details on how to respond to an alarm. If anyone
is feeling ill, EVACUATE your home immediately
and call 911.
Relocate your alarm. If frequent alarms continue,
have home rechecked for potential problems.
You may be experiencing an intermittent smoke
or CO problem.
®
is a registered trademark of BRK Brands, Inc.
®
is a registered trademark of the First Alert Trust.
Printed in Mexico M08-0094-000 K1 09/04