Asian Stanley International Co., Ltd.
●Installation of this product/ luminaire must be carried out by a qualified electrician in accordance with the national, local
electric and construction codes and regulations. Installation by unqualified person is prohibited by law.
Product Name
LLF0016A/LEN(1-4)/56/E/IN/A
LLF0016A/LEN(1-4)/72/E/IN/A
LLF0016A/LEN(1-4)/76/E/IN/A
LLF0016A/LEN(1-4)/80/E/IN/A
LLF0016A/LEN(1-4)/96/E/IN/A
Overall Dimensions
Maximum Projected area
IP classification
IK classification
Operation Temperature
Installation pole
Installation instructions
Attention at installation
WARNING
●Please ensure installation is in accordance with mounting instruction. Risk of product fall or fire.
●Do not use the product under the following environment and situation. It will cause electric shock and fire.
The unit will fall or not operate if not installed properly:
・Place exposed directly to organic solvent (Acetone, Ethyl ether, Hexane, etc.).
・Place where corrosive gas (Hydrogen sulfide, Chlorine, Ammonia, etc.)
and flammable gas (Hydrogen, Methane, etc.) is present.
・Places where flammable liquid (Gasoline, Kerosene, Fuel oil, etc.) is used.
・Places where humidity exceeds 90% or the product is affected by flood.
・Places covered by heat insulator and combustible material.
・Places where the product is buried under snow.
●Don't set it up in the place where the hazard is caused when the icicle drops. It causes the injury by the icicle fall.
●The insulation of the AC cable connected to the luminaire must be free from damage or cracks. -Risk of electric shock and fire.
●Do not disassemble this product, repair or replace any of its components. -Risk of electric shock, fire or the product fall.
●Do not use the product when broken or appears damaged in any way. -Risk of product fall, electric shock and fire.
●Please use the cable indicated on operation method with the performance beyond equality for a used cable.
It causes the electric shock, a fire, not lighting when other cables are used.
Instruction manual
Power
117W
150W
158W
167W
202W
Mount Height
Installer, please save a copy this instructions manual for retention and reference by the end user.
Incorrect handling of this product may cause serious personal injury, death and
damage to the product and property.
Road Light
Rated voltage
Rated Current
100V 1.17A
240V 0.49A
100V 1.50A
240V 0.63A
100V 1.58A
100~240V
240V 0.66A
100V 1.67A
240V 0.70A
100V 2.02A
240V 0.84A
734mm × 313mm × 151mm
Φ60.5mm (Length ≧135mm)
Control No. D00191296A
For retention and reference
frequency
Weight
50/60Hz
~10 kg
0.057 m
2
IP66
IK08
-20~50℃
6~14m
1/7

Advertisement

loading

Summary of Contents for Stanley LLF0016A

  • Page 1 Asian Stanley International Co., Ltd. Control No. D00191296A Road Light For retention and reference Instruction manual ●Installation of this product/ luminaire must be carried out by a qualified electrician in accordance with the national, local electric and construction codes and regulations. Installation by unqualified person is prohibited by law.
  • Page 2 Control No. D00191296A ●When abnormality occurs, turn off the power immediately and contact your distributor for assistance. Continued use of the product risks electric shock and fire. ●Do not connect to power source other than specified for the product. –Risk of electric shock, fire and product will not illuminate. ●Temper Glass may be damaged if a strong shock is applied.
  • Page 3: Installation Procedure

    Control No. D00191296A Installation procedure 1.Open cover Cover Latch Open Latch Open Top Cover Section : Housing Bolt / Screw Layout 2.Install pole by set screw M8. Recommended set screw M8 torque : 12.5 N·m 2.1 Move the Hexagonal Bolt M8 up. 2.2 Insert pole to Housing Bring the pole into contact with the pole stopper.
  • Page 4 Control No. D00191296A Electrical wire connection method 1.Install AC line cable to Cable gland by tightening the Cable gland. Recommended torque of Cable gland : 2.2 ~ 3.0 N·m Cable gland Requirement of input AC line cable ・Conductor of wire : 2.5 mm 3-Core : L(R/S/T), N, G ・Available cable sheath size : Φ6~Φ11mm AC line cable...
  • Page 5 Control No. D00191296A Electrical wire connection method 2.4) Assembly Terminal Block (Male) to Terminal Block (Female) by push together until tight. 2.5) Fix Block terminal with housing by using screw M3 Recommended screw M3 torque : 6.0 kgf・cm Block terminal (Female) Tighten by Screw M3 Assembly...
  • Page 6 Control No. D00191296A 取付説明 お客様へ、この説明書は必ず保管下さい Installation instructions Dear customer, please retain this instruction manual. 使用上のご注意 / Handling notes 取扱を誤った場合、人が死亡または重症を負う可能性があります 警告 / WARNING Incorrect handling of this product may cause serious personal injury, death and/ or damage to the product and property. ●お手入れの際は、取扱説明書に従って行って下さい。落下、感電、火災の原因となります。...
  • Page 7 For enquiry, please quote us the product model found on the label on the product. ● 電話番号など、変更になる場合があります。ホームページでご確認ください。 Our phone numbers printed in this manual may change. Please visit our homepage for the latest contact information. ASIAN STANLEY INTERNATIONAL CO.,LTD. 48/1 Moo 1 Kukwang Ladlumkaew, Pathumthanee 12140 Thailand TEL : +66 2 599 1260 スタンレー電気株式会社...