Download Print this page

Monarch MIT Series Owner's Manual

Self priming centrifugal pumps

Advertisement

Quick Links

OWNER'S
MANUAL
SAFETY WARNINGS
BEFORE OPERATING OR
INSTALLING THIS PUMP, READ
THIS MANUAL AND FOLLOW
ALL SAFETY RULES AND
OPERATING INSTRUCTIONS.
SAFETY
CAREFULLY READ THESE SAFETY
MESSAGES IN THIS MANUAL AND ON
PUMP.
CAUTION
DO NOT OPPERATE THIS PUMP DRY.
Review instructions before operating.
Never exceed recommended RPM.
Ensure proper rotation as indicated by arrow on pump
casing.
These pumps will operate satisfactorily at vertical lifts up to
25 feet when driven at full speed. In offset installations, friction
losses in the suction hose must be taken into consideration.
a ) PUMP LOCATION: The pump should be located on a
firm and level foundation in order to provide the best pos-
sible working conditions. If the pump is not properly
placed or blocked, it is liable to creep due to vibration.
Locating the pump as close as possible to the source
of water supply reduces the friction loss in the suction
hose and provides for maximum capacities.
b ) SUCTION HOSE: The suction hose should be the same
size as that of the pump suction tapping and should be
checked for collapsed inner lining, cuts, breaks, etc. If
the pump is installed any appreciable distance away
form the source of water supply, the suction hose should
be increased in size to reduce friction loss (this also
200027E-R4 0303
MIT SERIES
Self Priming Centrifugal Pumps
APPLICATION
INSTALLATION
c) WIRING: On electric motor driven units check the rota-
WARNING
Ensure input drives are properly aligned and guarded
before operating.
Keep all shield guards in place (this label is located on
the transmission housing).
increases the priming time). To prevent air pockets from
forming in the suction line, the suction hose must always
slope down towards the source of water supply. Thread
compound should be used on all pipe joints and connec-
tions should be thoroughly tightened. A strainer should
be installed on the bottom of the suction hose and should
be properly submerged.
tion of the pump with the arrow on the pump casing. In
the event of wrong rotation, refer to instructions furnished
with motor. The rotation of three phase motors can be
changed by interchanging any two leads to the motor.

Advertisement

loading

Summary of Contents for Monarch MIT Series

  • Page 1 MIT SERIES OWNER'S Self Priming Centrifugal Pumps MANUAL SAFETY WARNINGS BEFORE OPERATING OR INSTALLING THIS PUMP, READ THIS MANUAL AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS. SAFETY CAREFULLY READ THESE SAFETY MESSAGES IN THIS MANUAL AND ON PUMP. CAUTION WARNING DO NOT OPPERATE THIS PUMP DRY.
  • Page 2 OPERATION - PRIMING THE PUMP WARNING: DO NOT RUN THE PUMP BEFORE PRIMING IT, SINCE THE SEAL AND IMPELLER COULD BE PERMANENTLY DAMAGED. a) PRIMING: Never operate the pump dry as this may NOTE: The pump should also be drained after corrosive damage the seal.
  • Page 3 REPAIR TO ASSEMBLE: TO DISASSEMBLE: MIT-15 (Refer to Fig.2) 1. Clean all parts thoroughly before assembling. 1. Remove the four bolts (30) and then remove transmission 2. Oil rubber cup on stationary seat and push it into the head (1). adapter plate using thumbs only.
  • Page 4 LIMITED MONARCH INDUSTRIES WARRANTY For one year from date of purchase, Monarch Industries will replace or repair for the original purchaser, free of charge, any part or parts, found upon examination by any Monarch Industries Authorized Service Depot or by the Monarch factory, to be defective in material or workmanship or both.

This manual is also suitable for: