High Altitude Installations

High altitude installations are certified up to 10,200 ft (3,109 m).
Reference the respective Rinnai Tankless Water Heater Installation and Operation Manual to set the water
heater up for the altitude at which they will be operating.
High Altitude Derate
Tankless water heaters using common venting at altitudes over 2,000 ft (610 m) will automatically derate according to
the tables below. Use the tables below for calculating your total BTU for multiple tankless water heaters.
PROPANE (LP GAS)
Number
2,001 -
of Water
5,200 ft
Heaters
1
168,000
2
332,640
3
493,920
4
651,840
5
806,400
6
957,600
7
1,105,440
8
1,249,920
PVC/CPVC Common Venting Installation Instructions
Copyright © 2018 Rinnai America Corporation. All Rights Reserved.
NOTE
5,201 -
7,701 -
7,700 ft
10,200 ft
151,000
120,000
298,980
237,600
443,940
352,800
585,880
465,600
724,800
576,000
860,700
684,000
993,580
789,600
1,123,440
892,800
NATURAL GAS
Number
2,001 -
of Water
5,200 ft
Heaters
1
170,000
2
336,600
3
499,800
4
659,600
5
816,000
6
969,000
7
1,118,600
8
1,264,800
5,201 -
7,701 -
7,700 ft
10,200 ft
153,000
139,000
302,940
275,220
449,820
408,660
593,640
539,320
734,400
667,200
872,100
792,300
1,006,740
914,620
1,138,320
1,034,160