Fujitsu AU G18LVLB Series Service Instruction page 9

Split type room air conditioner
Hide thumbs Also See for AU G18LVLB Series:
Table of Contents

Advertisement

3. COOLING OPERATION (Auto : Cooling)
Switch the airflow [AUTO], and the indoor fan motor will run according to a room temperature,
as shown in Figure 5.
On the other hand, if switched in [HIGH]
operation modes QUIET, LOW, MED, HIGH, as shown in Table 5.
( Fig.5 : Airflow change - over ( Cooling : AUTO ) )
TR-Ts > 2 degC
=
2 degC > TR-Ts > 1 degC
=
1 degC > TR-Ts
4. DRY OPERATION (Auto : Dry)
Refer to Table 6. During the dry mode operation, the fan speed setting can not be changed.
5. INDOOR UNIT FAN CONTROL FOR ENERGY SAVING (Cooling mode)
Switch the airflow at cooling mode, and the indoor fan motor will run as shown in Fig.6.
It depends on the Function setting "Indoor unit fan control for energy saving."
( Fig.6 : Indoor Fan Control )
Compressor
ON
OFF
Indoor fan
Dry air flow
S-Lo
OFF
6. HEATING OPERATION (Auto : Heating)
Switch the airflow [AUTO], and the indoor fan motor will run according to a room temperature,
as shown in Figure 7.
On the other hand, if switched [HIGH]
operation modes QUIET, LOW, MED, HIGH, as shown in Table 5.
( Fig.7 : Airflow change - over ( Heating : AUTO ) )
TR-Ts > - 1 degC
=
- 1 degC > TR-Ts > - 2 degC
=
- 2 degC > TR-Ts
[QUIET], the indoor motor will run at a constant airflow of [COOL]
High mode
Med mode
Low mode
When the room
temperature drops
10
30
60
[QUIET], the indoor motor will run at a constant airflow of [HEAT]
When the room
temperature rises
Low mode
Med mode
High mode
When the room
temperature rises
TR-Ts > 2.5 degC
=
2.5 degC > TR-Ts > 1.5 degC
1.5 degC > TR-Ts
TR : Room temperature
Ts : Setting temperature
180
60
180
60 10
When the room
temperature drops
TR-Ts > - 1.5 degC
=
- 1.5 degC > TR-Ts > - 2.5 degC
- 2.5 degC > TR-Ts
01-06
=
30
(SEC)
TR : Room temperature
Ts : Setting temperature
=

Advertisement

Table of Contents
loading

Table of Contents