Sony KD-49X7 D Series Service Manual page 12

Table of Contents

Advertisement

Entry (Self Diagnosis Display)
- Go to the standby by a remote.
- Push the buttons sequentially:
<Display><5><Vol-><Power>
Exit
-If you want to finish service mode app, do AC OFF/ON
→*Service mode app is disable perfectly
-if you want to move home menu, push <HOME>button
→*Service mode app do background(not disable
perfectly)
Format of error timestamps
YYMMDDhhmmss (in UTC)
Example:
120823132523 -> Aug 23 2012 13:25:23 UTC
* Only when time is set, an error timestamp
is saved.
Panel Operation Time clear
<7> -> <0>
Timestamps and Error Count clear
<8> -> <0>
Total Operation Time and Boot Count clear
<9> -> <0>
Error Item
002
003
003
003
004
005
005
005
Smart Core Red
006
LED blinking
007
count
00005
Total Operation Time [hr] – Boot Count – Panel Operation Time [hr]
•Panel Operation Time is recorded every 30 min, but Total
Operation Time is recorded every 1 hr.
Therefore, the panel op. time might become larger than the
total op. time.
SELF CHECK
MAIN POWER
000000000000
DC ALERT
000000000000
AUD ERR
150101000018
TU DEMOD
150101000218
LD ERR
000000000000
TCON ERR
150101000504
P ID ERR
000000000000
FRCTC I2C
000000000000
BACKLIGHT ERR
000000000000
TEMP ERR
150101000200
00414
00002
Error
timestam
p for last
recorded
error
Error count
<<
000000000000
000000000000
000000000000
000000000000
150101000018
150101000018
150101000223
150101000105
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
000000000000
150101000002
000000000000
[Home]Exit
Error
Error
timestam
timesta
p for
mp for
second
3rd last
last
recorde
recorded
d error
error
12
000
000
003
003
000
001
000
000
000
002

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents