9. White balance adjustment
9.1. White balance adjustment (For details about the adjustment procedure, refer to "Kameyama Model Integrated Monitor
WB Adjustment Specification V1.92".)
Adjustment
Adjustment conditions
point
1
Setting
2
Automatic
[Command]
adjustment exe-
Process mode
cution
KRSW0001
KKT10037
Setting
KY0F0000
0SDS0001
SBSL0016
Multi-point adjustment mode
FACT0001
MSET0000
Point 2
WBI20180
MG2G****
MG2B****
MG2R****
Point 1
WBI10035
MG1G****
MG1B****
MG1R****
MAX
MGMG****
MGMB****
MGMR****
Writing
MSET0003
FACT0000
1) Set the unit to the following conditions.
AV MODE: [DYNAMIC]
Backlight: +16
Active Backlight: OFF
Aging Time: Min. 60 minutes
2) Connect the unit with the white balance adjustment jig.
[Adjustment procedure]
1) Send the "adjustment process" code using the remote control.
2) Set the point 2 to the specified gradation, specify the strongest color as the fixed
color, and adjust the RGB so that it becomes the standard value through the negative
adjustment.
3) Set the point 1 to the specified gradation, and set the G correction value (560 x G
value of point 2/2880) then adjust RB so that it becomes the standard value.
4) Calculate the RGB value of the maximum.
G(MAX) = 4080 x G(High) / 2880
R(MAX) = G(MAX) + R(High) - G(High)
B(MAX) = G(MAX) + B(High) - G(High)
(If G(MAX), R(MAX), B(MAX) > 4080, set as G(MAX), R(MAX), B(MAX) = 4080)
5) Enter the maximum value of the RGB values.
6) Reflect to DYNAMIC side 1 point value, 2 points and maximum values.(WCI*****)
7) Writes the adjustment value in MSET0003 command, turn off the AC power.
[Adjustment value]
* According to the "Standard settings" submitted by the Technical Department
[LC60LE660] teaching set
[Adjustment standard value]
Measuring instrument: [Minolta CA-210] Technical measuring instrument.
Level
Reference value
X=0.272
Point 2
180
y=0.277
X=0.272
Point 1
35
y=0.277
Brightness specification after adjustment.
Min 240cd/m2
5 – 10
LC-60/70LE660U,C6600U
Adjustment procedure
Adjustment spec
±0.0020
±0.0080
Inspection spec
±0.0040
±0.0160